14.0 FIELD INSTALLED ACCESSORIES

14.1 COMPRESSOR CRANKCASE HEATER (CCH)
While scroll compressors usually do not require crankcase heaters, there are
instances when a heater should be added. Refrigerant migration during the off cycle
can result in a noisy start up. Add a crankcase heater to minimize refrigeration
migration, and to help eliminate any start up noise or bearing "wash out."
TABLE 5
MAXIMUM SYSTEM CHARGE VALUES
Model
Size*
18
18
24
30
30
36
36
42
42
48
60
60
60
*These compressors come with the crankcase heater factory installed.
NOTE: The installation of a crankcase heater is recommended if the system charge
exceeds the values in Table 5.
All heaters are located on the lower half of the compressor shell. Its purpose is to
drive refrigerant from the compressor shell during long off cycles, thus preventing
damage to the compressor during start-up.
At initial start-up or after extended shutdown periods, make sure the heater is ener-
gized for at least 12 hours before the compressor is started. (Disconnect switch on
and wall thermostat off.)
14.2 LOW AMBIENT CONTROL (LAC) – COOLING MODE ONLY - RXAD-A08
This component senses compressor head pressure and shuts the heat pump fan off
when the head pressure drops to approximately 220 PSIG [1516.8 kPa]. This
allows the unit to build a sufficient head pressure at lower ambient in order to main-
tain system balance and obtain improved capacity. Low ambient control should be
used on all equipment operated below 70°F [21.1°C] ambient.
14.3 HIGH PRESSURE CONTROL (HPC)
This control keeps the compressor from operating in pressure ranges which can
cause damage to the compressor. This control is in the low voltage control circuit.
High pressure control (HPC) is a manual reset which opens near 610 PSIG [4205.8
kPa]. Do not reset arbitrarily without first determining what caused it to trip.

15.0 SERVICE

15.1 SINGLE-POLE COMPRESSOR CONTACTOR (CC)
CAUTION
Single-pole contactors are used on all standard single-phase units up
through 5 tons. Caution must be exercised when servicing as only one leg
of the power supply is broken with the contactor.
Compressor
Model Number
ZP16K5E-PFV
H82J183ABLA
ZP21K5E-PFV
ZP25K5E-PFV
H81J22BABCA
ZP31K5E-PFV
HRH031U1LP6
ZP36K5E-PFV
H83C363ABCA
ZP42K5E-PFV
ZP54K5E-PFV
ZP51K5E-PFV
HRH051U1L
Charge Limit
Without
Crankcase Heat*
8.0 lbs. [55.1 kPa]
9.0 lbs. [62.0 kPa]
8.0 lbs. [55.1 kPa]
8.0 lbs. [55.1 kPa]
*
8.0 lbs. [55.1 kPa]
8.0 lbs. [55.1 kPa]
10.0 lbs. [68.9 kPa]
12.0 lbs. [82.7 kPa]
10.0 lbs. [68.9 kPa]
*
10.0 lbs. [68.9 kPa]
12.0 lbs. [82.7 kPa]