TABLE 2
SUCTION LINE LENGTH/SIZE VS CAPACITY MULTIPLIER (R-410A)
Unit Size
Suction Line Connection Size
Suction Line Run - Feet [m]
Optional
25' [7.6]
Standard
Optional
Optional
50' [15.24]
Standard
Optional
Optional
100' [30.5]
Standard
Optional
Optional
150' [45.7]
Standard
Optional
NOTES:
*Standard line size
Using suction line larger than shown in chart will result in poor oil return and is not recommended.
1 1/2 Ton
2 Ton
3/4"
3/4"
[19] I.D.
[19] I.D.
5/8 [15.9] Opt.
5/8 [15.9] Opt.
3/4* [19] Std.
3/4* [19] Std.
1.00
1.00
1.00
1.00
0.98
0.98
0.99
0.99
0.95
0.95
0.96
0.96
0.92
0.92
0.93
0.94
2 1/2 Ton
3 Ton
3/4"
7/8"
[19] I.D.
[22.2] I.D.
5/8 [15.9] Opt.
5/8 [15.9] Opt.
3/4* [19] Std.
7/8* [22.2] Std.
7/8 [22.2] Opt.
1.00
1.00
1.00
1.00
1.00
0.96
0.98
0.98
0.99
0.99
0.94
0.96
0.96
0.97
0.97
0.91
0.94
0.93
0.95
0.95
3 1/2 Ton
4 Ton
7/8"
7/8"
[22.2] I.D.
[22.2] I.D.
3/4 [19] Opt.
7/8 [22.2] Opt.
7/8* [22.2] Opt.
1 1/8* [28.6] Std.
1.00
1.00
1.00
1.00
0.99
0.99
0.99
0.99
0.96
0.96
0.98
0.98
0.94
0.95
0.96
0.96
5 Ton
7/8"
[22.2] I.D.
7/8 [22.2] Opt.
1 1/8* [28.6] Std.
1.00
1.00
0.99
0.99
0.97
0.98
0.94
0.97
13