2.0 INSTALLATION (Continued)
To Install:
1. Uncrate carefully. Report any freight damage to the freight company immediately.
2. Set the unit in place. Be certain to maintain the minimum clearances from combustibles
and non-combustibles.
3. For an appliance supplied with legs, level the appliance using a spirit level. Should
flanged adjustable feet be provided, anchor to floor using proper anchoring devices.
4. Seal bolts and flanged feet with Silastic or other equivalent compound.
5. Be certain to leave adequate clearances for cleaning, maintenance and service.
WARNING: For an appliance equipped with casters, the installation
shall be made with a connector that complies with the standard for
connectors for moveable gas appliances, ANSI Z21.69-CSA 6.16 and a
quick-disconnect device that complies with the standard for quick-
disconnect devices for use with gas fuel, ANSI Z21.41-CSA 6.9;
adequate means must be provided to limit the movement of the
appliance without depending on the connector and the quick-
disconnect device or its associated piping to limit the appliance
movement; the location where the restraining means may be attached
to the appliance is on bottom of unit directly below relief valve.
If the unit is also equipped with an optional water fill valve it too must
be installed with a flexible water supply tube, a quick disconnect and
strain relief.
GAS CONNECTION:
CAUTION: The pipe thread compound used when installing pipes must
be a type that is resistant to the action of liquified petroleum or
propane gases.
NOTICE: If this equipment is being installed at over 2,000 feet altitude
and was not so specified on order, contact service department. Failure
to install with proper orifice sizing may void the warranty.