5.0 FRAMING

IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING
IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE
APPLIANCE ENCLOSURE BE "FINISHED" (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH
ANY OTHER OUTSIDE WALL OF A HOME. THIS WILL ENSURE THAT CLEARANCE TO
DO NOT NOTCH THE FRAMING AROUND THE APPLIANCE STAND-OFFS. FAILURE TO MAINTAIN
AIR SPACE CLEARANCE MAY CAUSE OVER HEATING AND FIRE. PREVENT CONTACT WITH
SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS. BLOCK
OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN-IN INSULATION. MAKE SURE
WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO
MAINTAIN CLEARANCES. FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS
LISTED MUST BE CONSTRUCTED ENTIRELY OF NON-COMBUSTIBLE MATERIALS. MATERIALS
CONSISTING ENTIRELY OF STEEL, IRON, BRICK, TILE, CONCRETE, SLATE, GLASS OR PLASTERS,
OR ANY COMBINATION THEREOF ARE SUITABLE. MATERIALS THAT ARE REPORTED AS PASSING
ASTM E 136, STANDARD TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE
FURNACE AT 750°C/1382°F AND UL763 SHALL BE CONSIDERED NON-COMBUSTIBLE MATERIALS.
MINIMUM CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED OR A SERIOUS FIRE HAZARD
THE APPLIANCE REQUIRES A MINIMUM ENCLOSURE HEIGHT. MEASURE FROM THE APPLIANCE
IF STEEL STUD FRAMING KITS WITH CEMENT BOARD ARE PROVIDED, THEY MUST BE
It is best to frame your appliance after it is positioned and the vent system is
installed. Use 2x4's and frame to local building codes.
For convenience, the standoffs have been shipped at. Before framing,
ensure the standoffs are opened and screwed in place. It is not necessary
to install a hearth extension, but the appliance should be raised to be ush
with either the hearth or the nished oor.
WARNING
!
RISK OF FIRE!
COMBUSTIBLES IS MAINTAINED WITHIN THE CAVITY.
INSULATION AND OTHER MATERIALS ARE SECURED.
COULD RESULT.
BASE.
INSTALLED.
71.1
WARNING
ATTENTION ATENCIÓN
LAS TRABAS PERMANECEN
LES ESPACEURS SONT
THE STANDOFFS HAVE
PLANAS DURANTE EL ENVÍO.
EMBALLÉS À PLAT. AVANT DE
BEEN SHIPPED FLAT.
CONSTRUIRE L'OSSATURE,
ANTES DE LA INSTALACIÓN,
BEFORE FRAMING
ASSUREZ-VOUS QUE LES
VERIFIQUE QUE LAS TRABAS
ENSURE THE STANDOFFS
SE PLIEGUEN HACIA ARRIBA
ESPACEURS SONT PLIÉS
ARE BENT UP AND
Y SE ATORNILLEN
ET FIXÉS EN PLACE À
SCREWED INTO PLACE.
CORRECTAMENTE.
L'AIDE DE VIS.