Download Print this page

Zanussi ZGG96524XX User Manual page 16

Advertisement

OTHER TECHNICAL DATA
TOTAL POW-
ER:
Electric supply:
Appliance cate-
gory:
Gas connec-
tion:
Appliance
class:
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
WARNING! This appliance does not
function with the existing gas settings
if installed in Malta. Therefore, before
connecting the appliance it is essential
to change the nozzles according to the
type of gas used according to the
table below.
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
NORMAL
BURNER
POWER kW
Multi Crown
3,65
Rapid
2,8
Semi-rapid
2,0
Auxiliary
1,0
16
Gas original:
G20 (2H) 20 mbar
Gas replace-
G30 (3+) 28-30 mbar
ment:
G31 (3+) 37 mbar
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse
II2H3+
R 1/2"
3
NORMAL POWER kW MINIMUM POWER kW
4,0
2,95
1,85
1,0
MINIMUM
POWER kW
1,4
0,95
0,6
0,33
1,4
0,75
0,6
0,33
NOMINAL GAS FLOW g/h
INJECTOR
MARK
G30 28-30 mbar
095
265
86
204
71
145
50
73
11,65 kW
832 g/h
818 g/h
INJECTOR MARK
146
119°
92
70
G31 37 mbar
261
200
143
71

Advertisement

loading