Installation Instructions

If the oven is to work properly, the kitchen housing must be suitable. The panels
of the kitchen unit that are next to the oven must be made of a heat resistant
material. Ensure that the glues of units that are made of veneered wood can
withstand temperatures of at least 120 °C. Plastics or glues that cannot withstand
such temperatures will melt and deform the unit. Once the oven has been lodged
inside the units, electrical parts must be completely insulated. This is a legal safety
requirement. All guards must be firmly fixed into place so that it is impossible to
remove them without using special tools. Remove the back of the kitchen unit to
ensure an adequate current of air circulates around the oven. The hob must have a
rear gap of at least 45 mm.
WARNING
This appliance is not fitted with other means for disconnection from the supply
mains having a contact separation in all poles that provide full disconnection
in under overvoltage category III conditions. Means for disconnection must
be incorporated in the fixed wiring in accordance with the wiring rules and
regulations.
Check the local utilities for electrical codes applied in the area. Failure to
wire the appliance according to governing rules may result in a hazardous
condition.
After installation show the customer where the isolating switch for the
appliance is located. This must be easily accessible with the installed
appliance.
This appliance is necessary to allow disconnection from the supply after
installation. The disconnection may be achieved by having the plug accessible
or by incorporating a switch in the fixed wiring in accordance with the wiring
rules.
The identification Name Plate bearing the technical data, model number and brand name is
visibly positioned in the oven (refer to page 7).
Do not remove this Name Plate for any reason.
The oven must be connected to earth in compliance with electrical system safety
regulations.
A fixed connection is to be used, fitting the power line with an omni-polar circuit breaker with
a contact opening gap equal to or greater than 3 mm, in an easily accessible position close
to the appliance.

IMPORTANT

Electrical Connection

Electrical work must be performed by a
legally qualified electrician.