Installation Of The Sensor - ELGO Electronic EMSC2 Series Operating Manual

Magnetic liner encoder with 1 vpp sine/cosine outputs
Table of Contents

Advertisement

7.2

Installation of the Sensor

For mounting the sensor two M3 screws are required.
Observe the mounting tolerances stated in section  7.2.2.
7.2.1
Alignment of Sensor / Magnetic Tape
Since the active sensor surface is not in the center of the sensor housing, it should be ensured that the sensor
head is aligned and mounted such that the active sensor surface is in the middle of the magnetic tape. This is
achieved in a simple manner and without additional equipment. Just use the correct side of the sensor (see fig-
ure below) and install it flush with the magnetic tape.
Standard (horizontal)
5
7.5
12.5
EMSC:
0.1... 0.8 mm
LMSC:
0.1... 2.0 mm
Figure 5: Alignment of the Sensor
Magnetic tape top view
Cable outlet
When mounting, please just make
sure that the sensor is flush with
the magnetic tape on this side.
The entire active sensor surface must be installed
within the permitted distance to the magnetic tape.
- 14 -
Top view
Option L (vertical)
EMSC:
0.1... 0.8 mm
LMSC:
0.1... 2.0 mm
Installation and First Start-Up
Cable outlet
12.5
17.5
Marker