Code
Meaning
Minimum number of monitored entrapment
60
protection devices (one) not installed.
61
CLOSE EYE/INTERRUPT held more than 3 minutes Check wired input on main control board; check for alignment or
62
CLOSE EDGE held more than 3 minutes
63
OPEN EYE/EDGE held more than 3 minutes
64
CLOSE EYE/INTERRUPT held more than 3 minutes Check wired input on expansion board; check for alignment or
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE/EDGE held more than 3 minutes
67
Wireless edge triggered more than 3 minutes
68
Wireless edge loss of monitoring
Wireless edge triggered
69
CLOSE EYE/INTERRUPT triggered, causing
70
reversal, preventing close, or resetting TTC
CLOSE EDGE triggered, causing reversal,
71
preventing close, or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
72
preventing opening
CLOSE EYE/INTERRUPT triggered, causing
73
reversal, preventing close, or resetting TTC
CLOSE EYE/EDGE triggered, causing reversal and
74
preventing close or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
75
preventing opening
Close input (EYE/EDGE) communication fault from
80
other operator
Open input (EYE/EDGE) communication fault from
81
other operator
Close input (EYE/EDGE) communication fault
82
(expansion board)
Open input (EYE/EDGE) communication fault
83
(expansion board)
Force Reversal (Operator 1)
91
Force Reversal (Operator 2)
92
RPM / STALL Reversal (Operator 1)
93
RPM / STALL Reversal (Operator 2)
94
99
Normal Operation
TROUBLESHOOTING
Installed System
External Entrapment
Informational
Protection
Solution
Review monitored entrapment protection device connections.
obstruction.
obstruction.
Check wired input for wiring issue or obstruction.
Check wireless edge inputs.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check inputs and wiring.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring on main control board.
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring on expansion board.
Check inputs and communication method between operators, either
wired bus or radio. Ensure operator is powered. May have to erase the
wireless communication and reprogram the two operators.
Check the connections between the main board and the expansion
board.
Check for obstruction. If no obstruction, check that the mechanical
assembly is engaged and free to move. See section on Limit and Force
Adjustment, and Obstruction Test.
Check for obstruction. If no obstruction, check the operator wiring and
that the mechanical assembly is engaged and free to move. Replace
APE assembly.
No action required
32
Inherent Entrapment
Protection
Saved
NO
YES
YES
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES