Installation; Quick Hook - Up And Testing - Helios RM-PSW2KVA Series User Manual

Pure sine wave inverter
Table of Contents

Advertisement

2-3 Installation:

Where to install;
The power inverter should be installed in a location that meets the following
requirements.
2-3-1 Dry – Do not allow water to drip or splash on the inverter.
2-3-2 Cool – Ambient air temperature should be between -20℃ and 50℃, the cooler
the better.
2-3-3 Safe – Do not install in a battery compartment or other areas where flammable
fumes may exist, such as fuel storage areas or engine compartments.
2-3-4 Ventilated – Allow at least one inch of clearance around the inverter for air flow.
Ensure the ventilation openings on the rear and bottom of the unit are not
obstructed.
2-3-5 Dust-free – Do not install the RM-PSW2KVA/E Inverter in a dusty environments
where are dust, wood particles or other filings/shavings. The dust can be
pulled into the unit when the cooling fan is operating.
2-3-6 Close to batteries – Avoid excessive cable lengths but do not install the
RM-PSW2KVA/E Inverter in the same compartment as batteries.
Use the recommended wire lengths and sizes (see section 2-6).
Also do not mount the RM-PSW2KVA/E Inverter where it will be exposed to the
gases produced by the battery.
These gases are very corrosive and prolonged exposure will damage the
RM-PSW2KVA/E Inverter.
2-4 Quick hooks – up and testing:
2-4-1 Unpack and inspect the power inverter, check to see that the power switch in the
OFF position.
2-4-2 Connect the cables to the power input terminals on the rear panel of power
inverter.
The red terminal is positive (+) and black terminal is negative (-).
Insert the cables into the terminals and tighten relative nut to clamp the wires
securely.
WARNING!
You may observe a spark when you make this connection
since current may flow to charge capacitors in the power
inverter.
Do not make this connection in the presence of flammable
fumes. Explosion or fire may result.
8