2-8 Cooling fan working code:

Cooling fan of inverter is through detecting output power and over temperature
situation to work.
When start to turn on the inverter and output power is under 300W, the cooling fan
does not start running. It complies with saving energy sources requirement. Until,
output power is up to 300W, the cooling fan will start to work in order to drop the
inner temperature.
If the ventilation opening is obstructed, the inverter will enter over temperature
protection mode (OTP). The cooling fan will continue working to drop the inner
temperature. When the temperature comes down to normal situation, the inverter
will turn on automatically.

3. Maintenance:

Very little maintenance is required to keep your inverter operating properly.
You should clean the exterior of the unit periodically with a dry cloth to prevent
accumulation of dust and dirt. At the same time, tighten the Screws on the DC input
terminals.

4. Troubleshooting guide:

Common problems – television interference:
Operation of the power inverter can interfere with television reception on some channels,
if this situation occurs, the following steps may help to alleviate the problems.
l Make sure that the chassis ground lug on the back of the power inverter is solidly
connected to the ground system of your vehicle, boat or home.
l Do not operate high power loads with the power inverter while watching
television.
l Make sure that the antenna feeding your television provides an adequate ("snow
free") signal and that you are using good quality cable between the antenna and
the television.
l Move the television as far away from the power inverter as possible.
l Keep the cables between the battery and the power inverter as short as possible
and twist them together about 2 to 3 twists per foot.
This mini radiated interference from the cables.
WARNING!
Do not open or disassemble the inverter. Attempting to
service the unit yourself may result in a risk of electrical
shock or fire.