220V Operation - Grizzly G0534 Instruction Manual

Downdraft sanding table
Hide thumbs Also See for G0534:
Table of Contents

Advertisement

220V Operation

Serious personal injury could occur if you
connect your machine to the power source
before you have completed the setup
process. DO NOT connect the machine to
the power source until instructed to do so.
Wiring
The Model G0534/G0535 is prewired for 110V
operation, but can be rewired to 220V. To rewire
for single-phase 220V, the plugs must be
changed and the motor must be rewired. When
rewiring, refer to the wiring diagram in Figure 3.
220 VOLT
MOTOR WIRES
3
1
Black
Figure 3.
G0534/G0535 220V Wiring Diagram.
Amperage Draw
The motor for your machine draws the following
amps at 220V:
G0534 ......................................................5 Amps
G0535 ......................................................7 Amps
A fire may occur if your particular electrical
configuration does not comply with local
and state codes. The best way to ensure
compliance is to check with your local
municipality or a licensed electrician.
G0534/G0535 Downdraft Tables
2
4
Green
GROUND
White
220 VOLT
POWER SUPPLY
FROM SWITCH
Circuit Breaker Requirements
Install your machine on a dedicated circuit to
reduce the possibility of overloading the circuit
and tripping the circuit breaker. If the circuit
breaker trips and the circuit is of the correct load
capacity, have the circuit inspected by a qualified
electrician. Never use a larger circuit breaker
than stated below, or you will increase the risk of
fire.
Circuit Breaker ............................10 Amp, 2 Pole
Plug Type
For 220V operation, this machine requires a
NEMA 6-15 plug and receptacle, as shown in
Figure 4.
Figure 4. Typical type 6-15 plug
and receptacle.
Your Shop Circuit Capacity
Always check to see if your circuit is capable of
handling the amperage draw from your machine,
as well as any other machines that could be oper-
ating on the same circuit. If you are unsure, con-
sult a qualified electrician.
Grounding
In the event of an electrical short, grounding
reduces the risk of electric shock by providing a
path of least resistance to disperse electric cur-
rent. This tool is equipped with a power cord that
has a plug with an equipment-grounding prong.
The outlet must be properly installed and ground-
ed in accordance with all local codes and ordi-
nances.
-7-