American Dryer AD-202 Installation Manual page 33

Phase 7 / f.s.s. – gas – dsi / steam / dual timer
Table of Contents

Advertisement

2. Technical Data
a. Gas Specifications
For Australia, refer to data plate.
Manifold Pressure*
In-Line Pressure
Shaded areas are stated in metric equivalents
* Measured at the gas valve pressure tap when the gas valve is on.
b. Gas Connections:
Inlet connection ------------- 1-1/2" N.P.T.
Inlet supply size ------------- 1-1/2" Pipe (minimum)
Btu/hr input (per dryer) ---- 590,000 (148,680 kcal/hr)
---------------------------------
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
Btu/hr**
Rating
590,000
470,000
404,000
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
** Check dryers rating plate.
Natural Gas ............................. #1
.................................................
L.P. Gas ................................... #28 = 0.1405" (3.5687 mm).
.................................................
113289 - 10
TYPE OF GAS
NATURAL
3.5 inches W.C.
6.0 - 12.0 inches W.C.
470,000 (118,517 kcal/hr) for 202 (AGA)
404,000 (101,874 kcal/hr) for 202DR
TYPE OF GAS
Natural
kcal/hr
Rating
Qty.
D.M.S.*
Part No.
148,680
4
#1
140840
118,517
4
#6
140833
101,874
4
#13
140860
= 0.2280" (5.7912 mm).
#6
= 0.2040" (5.1816 mm) for 202 (AGA)
#13 = 0.1850" (4.699 mm) for 202DR.
#31 = 0.1200 (3.048 mm) for 202 (AGA).
#33 = 0.1130" (2.870 mm) for 202DR.
www.adclaundry.com
LIQUID PROPANE
8.7 mb
10.5 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
Liquid Propane
Qty.
D.M.S.*
Part No.
4
#28
140821
4
#31
140818
4
#33
140855
26.1 mb
27.4 mb
Liquid
Propane
Conversion Kit
Part Number
882222
887249
882252
29