American Dryer AD-202 Installation Manual page 30

Phase 7 / f.s.s. – gas – dsi / steam / dual timer
Table of Contents

Advertisement

2. Electrical Service Specifications
IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the
case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
26
GAS AND STEAM
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY . For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
WIRE
PHASE
VOLTAGE
SERVICE
208
220
230
230
240
380
380
400 / 416
440
460 / 480
575
* 3 Wire is available.
ELECTRIC
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) type ONLY . For
others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
WIRE
PHASE
VOLTAGE
SERVICE
220
3
240
3
American Dryer Corp.
APPROX.
CIRCUIT
AMP DRAW
BREAKER
60 Hz
50 Hz
3
37
3
35
36
3
34
3
30
3
35
3
19
4*
18
4*
17
3
20
3
19
3
14
APPROX.
OVEN
CIRCUIT
AMP DRAW
kW
BREAKER
60 Hz
50 Hz
106
312
126
338
50
50
50
40
50
30
30
30
30
30
20
1/9/17
400
425
12/12/14
113289 - 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adg-202drMl-202Mlg-202dr