Remove Cardboard Template; Location Requirements; Product Dimensions - IKEA IMH172DS1 Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Remove Cardboard Template

The cardboard piece from the top of the microwave oven
packaging is perforated. The piece inside the perforation
is for use as a rear wall template.
1. Cut along the perforation to separate the template from the
rest of the cardboard packaging.
2. Set the cardboard template to the side and refer to it during
the "Mark Rear Wall" part of installation.

Location Requirements

Check the opening where the microwave oven will be installed.
The location must provide:
Minimum installation dimensions. See "Installation
Dimensions" illustration.
Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum C\," (10 mm) thickness drywall or plaster/lath within
cabinet opening.
Support for weight of 150 lbs (68 kg), which includes
microwave oven and items placed inside the microwave
oven and upper cabinet.
Grounded electrical outlet inside upper cabinet. See
"Electrical Requirements" section.
NOTES:
If installing the microwave oven near a left sidewall,
make sure there is at least 6" (15.2 cm) of clearance
between the wall and the microwave oven, so that
the door can open fully.
Some cabinet and building materials are not designed to
withstand the heat produced by the microwave oven for
cooking. Check with your builder or cabinet supplier to make
sure that the materials used will not discolor, delaminate or
sustain other damages.
Special Requirements
For Wall Venting Installation Only:
Cutout must be free of any obstructions so that the vent
fits properly, and the damper blade opens freely and fully.
For Roof Venting Installation Only:
If you are using a rectangular to round transition piece,
the 3" (7.6 cm) clearance needs to exist above the
microwave oven so that the damper blade can open freely
and fully. See "Rectangular to Round Transition" illustration
in "Venting Design Specifications" section.
Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See "Electrical Requirements" section.
(76.2 cm)
min.
66" (167.6 cm) min.
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/
cooktop below.
NOTE: To ensure good performance, do not obstruct top vent
airflow. If cabinets are deeper than 14" (35.6 cm), the unit must
be spaced out from the wall, using appropriate materials, which
are able to support 150 lbs (86 kg).
14"

Product Dimensions

*Overall depth of product will vary slightly depending on
door design.
A
B
12" (30.5 cm) min.
14" (35.6 cm) max.
upper cabinet and
30"
side cabinet depth
See note below.
30"
(76.2 cm)
typical*
14"
14"
Spacer
3

Advertisement

Table of Contents
loading