8 Natural gas G2.350 – 13 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
9 LPG G30/31 - 30/37 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
Rated flow rate G30 (g/h)
Rated flow rate G31 (g/h)
10 LPG G30/31 - 37 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
Rated flow rate G30 (g/h)
Rated flow rate G31 (g/h)
11 LPG G30/31 - 50 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
Rated flow rate G30 (g/h)
Rated flow rate G31 (g/h)
12 Town gas G110 – 8 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
13 Town gas G120 – 8 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
The nozzles not provided are available at Authorised Service Centres.
62
Installation
AUX
-
-
-
-
AUX
1.1
48
400
1.5
80
79
AUX
-
-
-
-
-
-
AUX
-
-
-
-
-
-
AUX
1.10
132
400
0.5
AUX
-
-
-
-
SR
RR
-
-
-
-
-
-
-
-
SR
RR
1.8
2.6
62
76
500
750
1.5
1.5
131
192
129
186
SR
RR
-
-
-
-
-
-
-
-
-
-
-
-
SR
RR
-
-
-
-
-
-
-
-
-
-
-
-
SR
RR
1.8
2.6
165
210
500
750
1
0.5
SR
RR
-
-
-
-
-
-
-
-
UR
-
-
-
-
UR
3.5
87
1600
10
254
250
UR
-
-
-
-
-
-
UR
-
-
-
-
-
-
UR
3.5
270
1400
1
UR
-
-
-
-