5 Installation

5.1 Safety instructions

Heat production during appliance
operation
Risk of fire
• Check that the carcase material is heat
resistant.
• Check that the carcase has the required
openings.
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
The minimum clearance between a
ventilation hood and the cooking
surface must be at least the
distance indicated in the ventilation
hood installation instructions.
The minimum clearances must also be
respected for the edges of the hob on the
back as indicated in the mounting
illustrations.
50
Installation

5.2 Section cut from the countertop

Create an opening with the dimensions
shown in the figure in the countertop of the
piece of furniture.
L (cm)
60 - 70 C
70 L
L: 70 cm models with lateral UR burner.
C: 70 cm models with central UR burner.
A (mm)
min 150 min 460 min 750 20 - 40
*If there is a kitchen unit positioned above the
hob. In the case of a hood, refer to the
measurements indicated in the relative manual.
The following operation requires
building and/or carpentry work
and must therefore be carried out
by a competent tradesman.
Installation can be carried out on
various materials such as masonry,
metal, solid wood or plastic
laminated wood as long as they
are heat resistant (>90°C).
X (mm)
555 - 560
675 - 680
B (mm) C (mm)* D (mm)
Y (mm)
478 - 482
478- 482
E (mm)
min 50