Setup

TC1S Test Unit Kit Components
50065726 TC1S Digital Indicator
50065734 TCC115S AC/DC Adapter/Charger (115 V)
50013424 Carrying Case
Force-sensing Accessories
50065742 TF70(S) Force Sensor (with or w/o ISDS)
max. 70 kN (7.7 tons)
50065750 TF130(S) Force Sensor (with or w/o ISDS)
max. 130 kN (14.6 tons)
50117980 MA50 Adapter for 1.5-ton tools
(used with TF70)
50108557 MA4 Adapter for 4-ton tools
(used with TF70)
50116614 MAMAP1 Adapter for 5-ton tools
(used with TF70)
50065769 MA22 Adapter for 6-ton tools
(used with TF70)
50065777 MA120 Adapter for 12-ton tools
(used with TF130)
50013416 MAVP Adapter for quad-point tools
(used with TF70)
52024054 MA12ID Adapter for 12ID indenter-type tools
(used with TF130)
Charging Instructions
1. Charge the TC1S for 14 to 16 hours before using the
tool for the first time.
2. Use only the TCC115S adapter/charger for the
TC1S.
Pressure
Transducer
Computer
Port
Greenlee / A Textron Company
Load
Cell
Charger
Port
5
Initialization Instructions
1. Press ON.
2. During the first 3 seconds of initialization, press P,
then F, and then
. Press Prog/Enter to initialize or
Clear to continue.
3. To set language, press SI/US and use
between "units" and "language". Press Prog/Enter
to complete the selection.
4. To set units, press SI/US and use
between "units" and "language". Select "SI/US" and
press Prog/Enter. Use
"US" units, and press Prog/Enter to complete the
selection.
5. To set date and time, press Prog/Enter and Output.
Use
to select "date" or "time". Use
Prog/Enter to adjust time and date.
Assembly Instructions
1. Select the proper force sensor and adapter accord-
ing to the tool output force.
2. Connect the force sensor interface cable into the
upper right jack of the TC1S Digital Indicator
(marked "F" on back of unit).
Select Force Sensor Value
1. Turn on the TC1S Digital Indicator.
2. Press Prog/Enter, and then press F.
3. Use
to select "*calibr.value", and then press
Prog/Enter.
4. Use
to position the cursor, and
value.
5. Set value to "70.0 kN" for the TF70(S) and "130.0
kN" for the TF130(S), and then press Prog/Enter.
6. The upper left corner of the TC1S display will
indicate "TF70S" or "TF130S".
Zero Point Correction
1. Be sure the load cell is not installed in the adapter.
2. Turn on the TC1S Digital Indicator.
3. Press Prog/Enter, and then press F.
4. Use
to select "set to zero".
5. Press Prog/Enter twice.