Recommended Hydraulic Fluids - Greenlee Fairmont H4645 Operation, Service And Parts Manual

Rail cut-off saw
Table of Contents

Advertisement

Specifications—Hydraulic Power Source (cont'd)
RESERVOIR
PUMP
POWER SOURCE

Recommended Hydraulic Fluids

Any non-detergent hydraulic fluid which meets the following specifications or HTMA specifications may be used.
S.U.S. @ 100 F (38 C) .......................................................................... 140 to 225
Flash Point ....................................................................... 340 F (170 C) minimum
Pour Point .......................................................................... -30 F (-34 C) minimum
Greenlee Textron Inc. / Subsidiary of Textron Inc.
Hydraulic Schematic
FILTER
(10 MICRON)
RELIEF
VALVE
2000 PSI
CONTROL
VALVE
@ 210 F (99 C) ....................................................................... 40 minimum
H4645 Rail Cut-Off Saw
Figure 2
COOLER
T
FLOW METER
P
7
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
TOOL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fairmont 48600