Greenlee DM-860 Instruction Manual page 19

Greenlee dm-860 digital meters: user guide
Hide thumbs Also See for DM-860:
Table of Contents

Advertisement

Available languages

Available languages

Accuracy (cont'd)
DC Current
Range
500.00 A
5000.0 A
50.000 mA
500.00 mA
5.0000 A
10.000 A*
*10 A continuous; 20 A maximum (Duty Cycle: 30 seconds on, 5 minutes off)
AC and DC + AC Voltage
Range
500.00 mV
5.0000 V
50.000 V
500.00 V
1000.0 V
Range
500.00 mV
5.0000 V
50.000 V
500.00 V
1000.0 V
* From 5% to 10% of range: Accuracy percentage of reading + 80 digits.
** From 5% to 10% of range: Accuracy percentage of reading + 180 digits.
Note: "Digits" refers to the least significant digit (the number in the right-most position.)
Accuracy
(0.15% + 0.2 A)
(0.1% + 2.0 A)
(0.15% + 0.01 mA)
(0.1% + 0.2 mA)
(0.5% + 0.001 A)
(0.5% + 0.02 A)
Accuracy* at
20 Hz to 45 Hz
(1.5% + 0.4 mV)
(1.5% + 0.004 V)
(1.5% + 0.04 V)
Unspecified
Unspecified
Accuracy* at
5 kHz to 20 kHz
(0.5% + 0.2 mV)
(0.8% + 0.002 V)
(0.8% + 0.02 V)
(0.5% + 0.2 V)
Unspecified
Accuracy* at
45 Hz to 300 Hz
(0.3% + 0.2 mV)
(0.8% + 0.002 V)
(0.8% + 0.02 V)
(0.4% + 0.4 V)
(0.4% + 4 V)
20 kHz to 100 kHz
DM-860
Burden Voltage
0.15 mV/ A
0.15 mV/ A
3.3 mV/mA
3.3 mV/mA
0.03 V/A
0.03 V/A
Accuracy* at
300 Hz to 5 kHz
(0.3% + 0.1 mV)
(0.4% + 0.004 V)
(0.4% + 0.04 V)
(0.4% + 0.4 V)
(0.8% + 4 V)
(300 Hz to 1 kHz)
Accuracy* at
(2.0% + 0.4 mV)
(4.0% + 0.004 V)**
(4.0% + 0.04 V)**
Unspecified
Unspecified
19

Advertisement

Table of Contents
loading

Table of Contents