Troubleshooting; Specifications - Greenlee CS-2072 Instruction Manual

Circuit breaker finder
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

Situation
No indication, i.e.,
no green LED
and buzzer.
Multiple indications
on second scan.
Tracing circuit
connected to light
fixture.

Specifications

Operating Conditions:
Temperature: 5 °C to 40 °C (41 °F to 104 °F)
Relative Humidity (non-condensing): 80% maximum for temperatures up to
31 °C (88 °F), decreasing linearly to 50% maximum at 40 °C (104 °F)
Altitude: 2000 m (6500') maximum
Indoor use only.
Storage Conditions:
Temperature: –29 °C to 66 °C (–20 °F to 150 °F)
Relative Humidity: 0% to 80% (non-condensing)
Remove battery from receiver.
Snap the transmitter and receiver together to store.
Transmitter Only
Voltage Range: 110–120 VAC, 60 Hz
Wattage: 3.0 W maximum
For use with NEMA 1-15R outlets or light socket adapter
Measurement Category: Category II, 120 V per UL 61010-1 (transmitter only)
Receiver Only
Battery: 9 V (NEDA 1604, JIS 006P, or IEC 6F22)
Battery Life: Approximately 50 hours with alkaline battery
Probable Causes
The breaker for that
circuit is not in the
box being scanned.
The first scan was
performed too
quickly.
Solutions
Scan the box that supplies that
circuit.
Scan again, moving the receiver
slowly. Be sure to keep the nose
of the receiver close to the
breaker and maintain proper
orientation.
Use an outlet adapter. Screw the
adapter into the socket, and then
plug the transmitter into it.
Or plug an extension cord into the
adapter, and then plug the
transmitter into the extension cord.
CS-2072