Figure 18.
The Selected parameters or function was
disappeared from the Welding Parameters Bar [44]
Figure 19.
Preflow Time
t1
shielding gas flows after the trigger is pulled
and prior to feeding.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Postflow Time
t2
shielding gas flows after the welding output
turns off.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Burnback Time is the amount of time that
the weld output continues after the wire
stops feeding. It prevents the wire from
sticking in the puddle and prepares the end of the wire
for the next arc start.
Adjust range: from OFF to 0.25 seconds (factory
default is set at Auto mode).
Spot Timer– adjusts the time welding will
continue even if the trigger is still pulled.
This option has no effect in 4-Step Trigger
Mode.
Adjust range: from 0 second (OFF) to 120 seconds
(factory default is OFF).
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Run-in WFS – sets the wire feed speed
from the time the trigger is pulled until an arc
is established.
Adjust range: from minimum to maximum WFS
(factory default is set at Auto mode).
English
adjusts the time that
adjusts the time that
The Start Procedure
and Volts (or Trim) for a specified time at the
beginning of the weld. During the start time,
the machine will ramp up or down from the Start
Procedure to the preset Welding Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
Crater Procedure – controls the WFS (or
value in ampere units) and Volts (or Trim) for
a specified time at the end of the weld after
the trigger is released. During the Crater time, the
machine will ramp up or down from the Weld Procedure
to the Crater Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
A/B procedure – enables quick weld
A/B
procedure change. The sequence changes
may occur between:
Two different welding programs.
Different settings for the same program.
Save Memory: Store the welding programs
with their parameters to one of the fifty user
Memories.
To save memory:
Add Save Memory icon to Welding Parameters Bar.
Use the Right Knob [36] to highlight the icon Save Memory.
Press the Right Knob [36] to confirm – the Save
Memory Menu is shown on the display .
Use the Right Knob to highlight the memory number
where the program would be stored.
Confirm the selection – Press and hold for 3 second
Right Knob [36].
16
controls the WFS
Figure 20.
Figure 21.
English