Start-Up Display Sequence; Outline Drawings - GE IC3645SR7T405T5 Installation And Operation Manual

Separately excited transistorized traction control
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL
IT TRANSISTOR CONTROL
Section 6.4 Start-Up Display Sequence

START-UP DISPLAY SEQUENCE

Key Switch On
Verify Each LED Segment
8 8 8 8
If Maintenance Code
Is Active
Display Code "-99"
For Four Seconds and
Activate Speed Limit
(if selected)
BDI Display or
Blank Display
(no BDI used)
Run Mode
BDI Display or
Blank Display
(no BDI used)
Key Switch
Display Traction Hourmeter
For Four Seconds
Display Pump Hourmeter
For Four Seconds
If Maintenance Code
Is Not Active
Diagnostics Override
With Fault
Diagnostics Override
With Fault
Off
Section 6.5 Outline Drawings
g
0.41
(10.4)
CONNECTOR OMITTED
IF NOT REQUIRED
0.19
(4.8)
1
2
3
4
BACK VIEW OF DISPLAY
5
4
3
2
Page 43
GE Electric Vehicle
Motors & Controls
+
-
3.20 (81.3)
PUMP
TRACTION
PY3
PY4
PY2
PY1
PUMP
5
Wiring connections to "Y"
plugs of Traction & Pump
controls.
1
TRACTION
PY3
PY4
PY2
PY1
PY5
April 2012