DIAGNOSTIC STATUS CODES
IT TRANSISTOR CONTROL
TRACTION
STATUS CODE
Rolling Radius or Gear Ratio or Top Speed
-14
parameters are out of limits for the motor.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Traction
Functions 13 , 16 or 21 is programmed to
Controller
an incorrect value.
Reprogram the above functions to the
proper value and the status code should
clear.
TRACTION
STATUS CODE
Battery voltage is too low at initial key
-15
switch closure.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Discharged battery
Traction
 Check battery voltage to confirm that it is a minimum
Controller
of 68.3 volts. Charge battery, if required.
Defective battery
 Check each battery cell for proper voltage (greater
than 1.95 volts at cell). Replace or repair battery.
Incorrect control card adjustment.
 Check Function 15 for proper adjustment for battery
being used. See Handset instruction sheet for
details. Adjust to proper settings.
Check "minimum" battery volts at P1 & NEG.
DESCRIPTION OF STATUS
CORRECTIVE ACTIONS
DESCRIPTION OF STATUS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the
Rolling Radius or Gear Ratio or Top Speed
perimeters are out of limits for the motor.
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE
CAUSE OF STATUS INDICATION
This status code will be displayed when the
battery volts are less than 68.3 volts at initial key
switch on.
TROUBLE-SHOOTING DIAGRAM
LINE
FU1
+
72 VDC
POS
A 1
F1
-
POWER CONNECTIONS
NEG
A 2
F2
Page 23