Troubleshooting (cont'd)
PROBLEM
Tool operates slowly. (cont'd)
Tool operates too fast.
Tool feels hot.
Tool leaks hydraulic fluid.
Greenlee Textron / Subsidiary of Textron Inc.
H6200B / 42247 Chain Saw
PROBABLE CAUSE
Hydraulic fluid viscosity too heavy.
Tool components loose.
Dirt, contaminants, etc., in tool
components.
Tool components worn or damaged.
Power source components not
adjusted correctly.
Hydraulic fluid level low.
Hydraulic fluid viscosity too light.
Hydraulic fluid dirty.
Tool control valve stuck in partial
power-ON position.
Power source components not
adjusted correctly.
Dirt, contaminants, etc., in tool
components.
Worn or damaged O-rings or gaskets.
Tool components worn or damaged.
Guide bar oil port plugged.
Tool components loose.
Tool components worn or damaged.
21
POSSIBLE REMEDY
Use fluid viscosity recommended.
See Recommended Hydraulic Fluids.
Tighten component hardware.
Disassemble tool and clean
components.
Disassemble tool. Replace worn or
damaged components.
Refer to power source operator's
manual for recommended speed,
flow and pressure settings.
Check fluid level. Fill to FULL mark.
Check system for leaks.
Use viscosity recommended. See
Recommended Hydraulic Fluids.
Drain reservoir, flush and fill with
clean fluid. Change filter.
Free spool so it returns to neutral
position.
Refer to power source operator's
manual for recommended speed,
flow, and pressure settings.
Disassemble tool, and clean
components.
Replace worn or damaged O-rings
or gaskets.
Disassemble tool. Replace worn or
damaged components.
Remove chain and guide bar. Clean
oiler port in guide bar.
Tighten component hardware.
Disassemble tool. Replace worn or
damaged components.