Skymsen LAR-10MB Instruction Manual

Skymsen LAR-10MB Instruction Manual

Industrial
Hide thumbs Also See for LAR-10MB:

Advertisement

Available languages

Available languages

Quick Links

Instructions Manual / Manual de Instrucciones
Industrial Blender / Licuador Industrial
Model / Modelos
Office
Phone: 1-800-503-7534 / 305-868-1603
LAR-10MB
Fax: 305-866-2704
sales@skyfood.us -
www.skyfood.us
TOLL FREE 1-800-503-7534
41458.1 - July / 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LAR-10MB and is the answer not in the manual?

Questions and answers

Summary of Contents for Skymsen LAR-10MB

  • Page 1 Instructions Manual / Manual de Instrucciones Industrial Blender / Licuador Industrial Model / Modelos Office Phone: 1-800-503-7534 / 305-868-1603 LAR-10MB Fax: 305-866-2704 sales@skyfood.us - www.skyfood.us TOLL FREE 1-800-503-7534 41458.1 - July / 2013...
  • Page 3 SUMMARY / INDICE 1. ENGLISH 2. ESPAÑOL LAR - 10MB LAR - 10MB...
  • Page 4: Table Of Contents

    SUMMARY 1. Introduction 1.1 Safety 1.2 Main Components 1.3 Technical Characteristcs 2. Installation and Pre Operation 2.1 Installation 2.2 Pre Operation 3. Operation 3.1 Starting 3.2 Feeding Procedures 3.3 Cleaning 4. General Safety Practices 4.1 Basic Operation Procedures 4.2 Safety Procedures and Notes Before Switching the Machine On 4.3 Routine Inspection 4.4 Operation 4.5 After Finishing the Work...
  • Page 5: Introduction

    1. Introduction service company ("Service Company"). Products held at commercial facilities and weighing less than seventy (70) lbs. must be taken or shipped, shipping charges are prepaid, either Safety to SKYFOOD's facility or to a Service Company. Mileage or travel time will NOT be paid. SKYFOOD offers a limited on-site warranty for products ONLY held at commercial The High Performance Industrial Blenders are machines simple to use and to facilities, whose net weight exceeds seventy (70) lbs., provided they are installed in a...
  • Page 6: Technical Characteristcs

    SKYFOOD EQUIPMENT LLC - SERVICE Technical Data Technical Data Units Units LAR-10MB For questions or assistance with products FLEETWOOD by SKYMSEN and SKYMSEN, Voltage 127 / 220 call SKYFOOD EQUIPMENT Toll Free : 1-800-503-7534, 24h Customer support, or visit Frequency [Hz] 50 ou 60(*) the Customer Service section of www.skyfood.us.
  • Page 7: Operation

    Tabla - 02 Before using the machine all parts that get in contact with food must be washed with running water and neutral soap. To clean your Blender read item 3.3 Cleaning on this Manual (pag.4). Problemas Causas Soluções Falta de Energia Verifique si el * La Máquina no se prende.
  • Page 8: Cleaning

    DESCONÉCTELA FÍSICAMENTE DE LA RED ELÉCTRICA, DURANTE TODA LA OPERACIÓN DE MANUTENCIÓN. The new SKYMSEN Blenders models were developed for easy cleaning. Wash the removable parts with running water and neutral soap and wipe up the others with a IMPORTANTE damp cloth.
  • Page 9: General Safety Practices

    El accionamiento de un comando manual (botón, llave eléctrica, palanca, 4. General Safety Practices etc.) debe ser hecho siempre después que se tenga la certitud de que es el comando correcto. IMPORTANT If any item from the GENERAL SAFETY NOTIONS section is not applicable to Cuidados 4.2.3 your product, please disregard it.
  • Page 10: Safety Procedures And Notes Before Switching The Machine On

    Antes de accionar cualquier comando manual (botones, llaves eléctricas, palancas, etc.) verifique siempre si el comando es el correcto, o en caso de dudas, 4.2 Safety Procedures and Notes Before Switching Machine ON consulte este Manual. Nunca toque ni accione un comando manual (botones, llaves eléctricas, IMPORTANT palancas, etc.) por acaso.
  • Page 11: Operation

    Siga el siguiente procedimiento para la remoción de las partes removibles: 4.4 Operation 4.4.1 Advice Desconecte la maquina de la red eléctrica. Be sure your hair is not loose in order to avoid getting caught by turning parts Retire la Tapa Nº 01 y el Vaso Nº 02 (Fig.01). which could lead to a serious accident.
  • Page 12: Electric Diagram

    Vaso tome cuidado con la cuchilla. Voltage Selector Switch Los modelos de Licuadoras SKYMSEN fueron proyectados para facilitar la limpieza de la maquina. Para hacer la limpieza, lave las partes removibles con agua y jabón neutro y en las demás pase solamente un paño húmedo.
  • Page 13 Antes de encender el equipo verifique si el voltaje de la maquina es el mismo que lo de la red eléctrica, 110 o 220V. Si necesario ajústelo utilizando la Llave Selectora de Voltaje Nº 07 (Fig.01) ubicada en la parte ÍNDICE inferior de la maquina.
  • Page 14 INTRODUCCIÓN Principales Componentes 1.1 Seguridad Todos los componentes que incorporan la maquina son construidos con materiales cuidadosamente seleccionados para su función, dentro de Las Licuadoras Industriales de Alto Rendimiento, son maquinas los padrones de prueba y de la experiencia de SIEMSEN. simples de se operar y de fácil limpieza, sin embargo para su mayor seguridad lee las instrucciones abajo para evitar accidentes: Foto –...