Transferring Bank Data; Alarm Output - Omron ZG2-WDS8T User Manual

Hide thumbs Also See for ZG2-WDS8T:
Table of Contents

Advertisement

Note
Measurement cycle
When the Data Storage Unit is connected, the measurement cycle of the Sensor Controllers
increases according to the display mode of the Sensor Controller.
• Profile display: approx. 150 to 300 ms (varies according to profile shape)
• Digital display: approx. 50 ms per displayed task (i.e. approx. 200 ms when four tasks are
displayed)
To set the fastest measurement cycle, use the Sensor Controllers with the display OFF (ECO
monitor).

Transferring Bank Data

OFF
BUSY signal
ON
Process
(1) Transfer of bank data Bank data is transferred between the Sensor Controller and Data
(2) Process executing

Alarm Output

OFF
Sensor Controller
judgment output
ON
OFF
Data Storage Unit
alarm output
ON
Process
T1: Alarm output delay
time
ZG2-DSU User's Manual
(1) Transfer of bank data
(2) Process executing
Description
Storage Unit. Transfer operation is performed by using serial
communication commands or menu operations.
During transfer of bank data, the BUSY signal is turned ON. New
operation instructions cannot be accepted while the BUSY signal is
ON.
T1
Description
This is the delay time from when the measurement value is applied
on the Sensor Controller up to output of the alarm on the Data
Storage Unit.
1 ms or less
57
Timing Charts

Advertisement