Daikin LRYEN-AY1 Installation And Operation Manual page 19

Co₂ conveni-pack outdoor unit and capacity up unit
Table of Contents

Advertisement

E
D
F
3
3
H4
H3
f
e
d
1
Capacity up unit (LRNUN5*)
2
Outdoor unit (LRYEN10*)
3
Indoor unit (showcase)
4
Indoor unit (blower coil)
5
Indoor unit (air conditioning)
A~J
Liquid piping (side showcases and blower coils)
A2~E2
Liquid piping (side air conditioning)
a~g
Gas piping (side showcases and blower coils)
a2~e2
Gas piping (side air conditioning)
H1~H4
Height difference
In case the required pipe sizes (inch sizes) are not available, it is
also allowed to use other diameters (mm sizes), taken the following
into account:
▪ Select the pipe size nearest to the required size.
▪ Use the suitable adapters for the change-over from inch to  mm
pipes (field supply).
▪ The additional refrigerant calculation has to be adjusted as
mentioned in the following chapters:
▪ For outdoor unit without capacity up unit:
amount" [ 4  32].
additional refrigerant
▪ For outdoor unit with capacity up unit: see
amount" [ 4  32] but additional refrigerant is
additional refrigerant
not needed because the capacity up unit is already precharged.
Piping size between outdoor unit and first branch
When the equivalent pipe length between outdoor unit and the
furthest indoor unit is 90 m or more (b+d), the size of the main gas
pipe (b) must be increased (size-up). If the recommended gas pipe
(size-up) is not available, you must use the standard size (which
might result in a small capacity decrease).
a
d
b
c
a
Outdoor unit
b
Main gas pipe
c
First refrigerant branch
d
Piping between indoor unit and refrigerant branch
e
Furthest indoor unit
System side
Refrigeration
Air conditioner
LRYEN10A7Y1+LRNUN5A7Y1
CO₂ Conveni-Pack outdoor unit and capacity up unit
4P605461-1B – 2020.08
1
B
A
C
G
4
H4
J
4
H1
g
j
c
a
"15.2  To determine
"15.2  To determine
e
Piping outer diameter size
(a)
(mm)
Liquid side
Gas side
Ø12.7×t0.85
Ø15.9×t1.05
(K65)
(K65)
Ø15.9×t1.05
Ø19.1×t1.3
(K65)
(K65)
2
A2
B2
C2
E2
5
5
D2
5
H1
a2
e2
d2
b2
c2
(a)
For refrigeration piping (A, B, a) and for air conditioner piping (A2,
a2)
Piping size between branching areas or between
first and second branch
Indoor unit capacity
index (kW)
Refrigeration side: liquid pipe
x≤10.0
10.0<x
Refrigeration side: gas pipe
x≤6.5
6.5<x≤14.0
14.0<x
Air conditioner side: liquid pipe
Air conditioner side: gas pipe
(a)
Piping between branching areas (C, D, c, d)
(b)
Piping from first branch to second branch (B2, b2)
Piping size from branch to indoor unit
Piping outer diameter size (mm)
Gas pipe
Refrigeration side
Same size as C, D, c, d.
If piping sizes of the indoor units are different, connect a reducer
close to the indoor unit to align piping sizes.
Air conditioner side
Ø12.7×t0.85 (K65)
(a)
Piping from branch to indoor unit (E, F, G, J, e, f, g, j)
(b)
Piping from branch to indoor unit (C2, D2, E2; c2; d2; e2)
13 Piping installation
H2
Piping outer diameter size (mm)
(a)
Ø9.5×t0.65 (K65)
Ø12.7×t0.85 (K65)
(a)
Ø9.5×t0.65 (K65)
Ø12.7×t0.85 (K65)
Ø15.9×t1.05 (K65)
(b)
Ø12.7×t0.85 (K65)
(b)
Ø15.9×t1.05 (K65)
Liquid pipe
(a)
(b)
Ø9.5×t0.65 (K65)
Installation and operation manual
19