Connection Of The Indoor Unit Power Supply And Communication Cable(S); Installation Of The Remote Controller - Daikin EKHBRD016ABV1 Installation Manual

Indoor unit for air to water heat pump system
Hide thumbs Also See for EKHBRD016ABV1:
Table of Contents

Advertisement

Connection of the indoor unit power supply and
communication cable(s)
Cable requirements
Cable
Item
bundle Description
In case of normal kWh rate power supply
installation
1
PS
Normal kWh rate power
supply
In case of benefit kWh rate power supply
installation
1
HV
Normal kWh rate power
supply
2
PS
Benefit kWh rate power
supply
3
LV
Outdoor unit communication
(F1/F2)
4
LV
Standard remote controller
(P1/P2)
5
LV
Secondary remote controller
(a)
(P1/P2)
6
LV
Domestic hot water tank
(a)
thermistor (R2T)
7
LV
External room thermostat
(a)
signal ON/OFF
8
LV
Benefit kWh rate power
supply switch (S1S)
9
LV
Multiple set point signal 1
10
LV
Multiple set point signal 2
(a)
11
LV
Heater kit signal
12
HV
Bottom plate heater (E7H)
13
HV
3-way valve (K1S)
14
HV
External room thermostat
(a)
power supply
(a)
15
HV
Heater kit control
16
HV
Solar pump station relay
PS = Power supply (see
LV = Low voltage (see
figure
HV = High voltage (see
(a) Optional
(b) Refer to the nameplate on the indoor unit.
(c) Minimum cable section 0.75 mm
(d) This device and connection cable is delivered with the domestic hot water tank.
NOTE
Select all cables and wire sizes in accordance with
relevant local and national regulations.
After finishing the electric work, confirm that each electric
part and terminal inside the electric parts box is connected
securely.
Procedure
1
Open the unit and put the switch box in front of the unit as
described in
"Opening the unit" on page
2
Open the switch box cover.
3
Using the appropriate cable, connect the power supply and
communication cable(s) to the appropriate terminals as shown
on the wiring diagram and according to
To avoid receiving electric noise, be sure that the
cables are put in the correct bundle and routed in
the correct bundle tray as shown in
When wiring, route the cable bundles that are
outside the unit away from each other by at least
25 mm in order to avoid receiving electric noise
(external noise).
Be sure to route all cables between the unit side
plate and the wiring retention bar as shown in
figure
3.
EKHBRD011~016ABV1+Y1
Indoor unit for air to water heat pump system
4PW60970-1B
Required number
of conductors
1~
3~
2+GND
4+GND
1~
3~
2+GND
2+GND
2+GND
4+GND
2
2
2
2
2
2
2
2
2
2
2
2
(a)
(a)
2
2
(a)
2
2
Refer to the installation manual
of the heater kit
(a)
2
2
(a)
3
3
2
2
Refer to the installation manual
of the heater kit
(a)
2
2
figure
3)
3)
figure
3)
2
.
35.
figure
3.
figure
4
Fix the cables with cable ties to the cable tie mountings to
ensure strain relief and to make sure that it does not come in
contact with the piping and sharp edges. Never squeeze
bundled cables.
Note: only relevant field wiring is shown in
Maximum
running
5
Close the switch box cover and install the switch box back into
current
the unit by following the instructions described in
unit" on page 35
(b)

Installation of the remote controller

The unit is equipped with a remote controller offering user-friendly
way to set up, use and maintain the unit. Before operating the remote
1.25
controller, follow this installation procedure.
(b)
–1.25
NOTE
(c)
(c)
(c)
(d)
(c)
100 mA
(c)
100 mA
(c)
100 mA
(c)
100 mA
(c)
0.5 A
(d)
(c)
1
Remove the front part of the remote controller.
100 mA
Insert a slotted screwdriver into the slots (1)
in the rear part of the remote controller, and
remove the front part of the remote
(c)
100 mA
controller.
2
Fasten the remote controller on a flat
surface.
NOTE
3
Wire the unit.
NOTE
3.
in reverse order.
The wiring for connection is not included.
The remote controller, delivered in a kit, has to be
mounted indoors.
When the remote controller thermostat function is
used, select the installation location considering it
should be a place:
-
where the average temperature in the room can be
detected,
-
that is not exposed to direct sunlight,
-
that is not near a heat source,
-
that is not affected by outside air or air draught due
to e.g. door opening/closing,
-
where the display is kept clean,
-
where the temperature is between 0°C and 50°C,
-
where the relative humidity is maximum 80%.
Be careful not to distort the shape of the lower
part of the remote controller by over tightening the
mounting screws.
If next to the standard remote controller the
optional remote controller is installed as well:
Connect the electrical wires of both remote
controllers in the same way like described
below.
Select a master and a slave remote controller
by switching the SS1 selector switch.
PCB
S S
SS1
M
Only the remote controller set as master can
work as room thermostat.
figure
3.
"Opening the
1
S
Slave
M
Master
Installation manual
16