Daikin Altherma EAVX-D9WG Installer's Reference Manual page 80

Low temperature split
Hide thumbs Also See for Altherma EAVX-D9WG:
Table of Contents

Advertisement

12 Troubleshooting
Error code
Detailed error
code
E5
00
E6
00
E7
00
E7
62
E8
00
E9
00
EA
00
EC
00
EC
04
F3
00
F6
00
FA
00
H0
00
H0
01
H1
00
H3
00
H4
00
H5
00
H6
00
H8
00
H9
00
HC
00
HC
01
HJ
10
HJ
11
HJ
12
J3
00
J5
00
J6
00
J6
07
J6
32
J6
33
J7
12
Installer reference guide
80
Description
OU: Overheat of inverter
compressor motor
OU: Compressor startup defect
OU: Malfunction of outdoor unit
fan motor
Brine flow abnormality
OU: Power input overvoltage
Malfunction of electronic
expansion valve
OU: Cool/heat switchover
problem
Abnormal increase tank
temperature
Tank preheating
OU: Malfunction of discharge
pipe temperature
OU: Abnormal high pressure in
cooling
OU: Abnormal high pressure,
actuation of HPS
OU: Voltage/current sensor
problem
Brine flow switch malfunction
External temperature sensor
problem
OU: Malfunction of high pressure
switch (HPS)
Malfunction of low pressure
switch
Malfunction of compressor
overload protection
OU: Malfunction of position
detection sensor
OU: Malfunction of compressor
input (CT) system
OU: Malfunction of outdoor air
thermistor
Tank temperature sensor
problem
Second tank temperature sensor
problem
Water pressure sensor
abnormality
Boiler abnormality detection
Bypass valve turning error
OU: Malfunction of discharge
pipe thermistor
Malfunction of suction pipe
thermistor
OU: Malfunction of heat
exchanger thermistor
OU: Malfunction of heat
exchanger thermistor
Leaving water temperature
thermistor Abnormality (outdoor
unit))
Sensor communication error
Brine inlet thermistor abnormality
Error code
Detailed error
code
J8
00
J8
07
JA
00
JA
17
L1
00
L3
00
L4
00
L5
00
L8
00
L9
00
LC
00
P1
00
P3
00
P4
00
PJ
00
U0
00
U1
00
U2
00
U3
00
U4
00
U5
00
U6
36
U7
00
U8
01
U8
02
U8
03
U8
04
U8
05
U8
06
U8
07
U8
08
UA
00
UA
17
UA
21
UA
22
EPGA11~16DAV3 + EAVH/X16S18+23DA6V+9W
Description
Malfunction of refrigerant liquid
thermistor
Brine outlet thermistor
abnormality
OU: Malfunction of high pressure
sensor
Refrigerant pressure sensor
abnormality
Malfunction of INV PCB
OU: Electrical box temperature
rise problem
OU: Malfunction of inverter
radiating fin temperature rise
OU: Inverter instantaneous
overcurrent (DC)
Malfunction triggered by a
thermal protection in the inverter
PCB
Prevention of compressor lock
Malfunction in communication
system of outdoor unit
Open-phase power supply
imbalance
Abnormal direct current t
OU: Malfunction of radiating fin
temperature sensor
Capacity setting mismatch
OU: Shortage of refrigerant
Malfunction by reverse phase/
open-phase
OU: Defect of power supply
voltage
Under floor heating screed dryout
function not completed correctly
Indoor/outdoor unit
communication problem
User interface communication
problem
Boiler standby abnormality
OU: Transmission malfunction
between main CPU- INV CPU
Connection with LAN adapter lost
Connection with room thermostat
lost
No connection with room
thermostat
Unknown USB device
File malfunction
Boiler communication error
P1P2 communication error
Boiler communication error
Indoor unit, outdoor unit matching
problem
Tank type problem
Extension/hydro mismatch
problem
Communication problem between
control box and option box
Daikin Altherma – Low temperature split
4P556070-1 – 2019.02