Daikin INTERGAS Altherma NHY2KOMB28AA Installer's Reference Manual page 96

Hide thumbs Also See for INTERGAS Altherma NHY2KOMB28AA:
Table of Contents

Advertisement

17 Technical data
MRM*, MR30
Magnetic relay
(PCB1)
M1C
Compressor motor
M1F
Fan motor
PAM (PCB1)
Pulse-amplitude modulation
PCB1
Printed circuit board (main)
PS (PCB1)
Switching power supply
Q1L
Thermal protector
R1T
Thermistor (outdoor air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (compressor discharge)
Electrical connection diagram in case of NHY2KOMB28+32AA gas boiler
For more details, please check the unit wiring.
TYPICAL CONFIGURATION
OUTDOOR
INDOOR
Boiler
Power supply
unit power supply:
230 V + earth
FIELD SUPPLY
DHW PUMP
OPTIONAL PART
Bottom plate heater
Power supply
3 core
unit power supply:
230 V + earth
OPTIONAL PART
DOMESTIC HOT WATER TANK
R5T - thermistor water temperature
3-WAY VALVE
M3S (when tank is installed)
selection domestic hot water–floor heating
Installer reference guide
96
Standard: 2 low voltage wires
2 low voltage wires
STANDARD PART
OUTDOOR UNIT - HYDRO
3 core
X2M: 1-2-3
3 core
X2M: 1-5-6
230V
A1P: X14A-earth
BOILER BOX
INDOOR
X2: 2-4-earth
X4: 9-10
signal
X2: 3-5-6
230 V
S1PH
SA1 (PCB1)
S* (PCB1)
U, V, W (PCB1)
V* (PCB1)
X11A
X*M
Y1E
Y1S
Z*C
Z1F (PCB1)
Notes:
- In case of signal cable: keep minimum distance to power cables >5 cm
- Available heaters: see combination table
-
: field supplied
- Field setting: [C-02]=0
Only for EKRSCA1
X5M: 5-6
External outdoor temperature sensor
2 core
Only for EKRUHML*
2×0.75
X5M: 1-2
A14P: P1-P2 user interface
communication
2 core
2×0.75
communication
Only for BRP069*
A13P: P1-P2 LAN adapter
1
Only for EKRTW
(wired room thermostat)
2 core
A3P: X1M:
X4: 6-7
C-com-H
230 V
1
Only for EKRTR
(wireless room thermostat)
2 core
A4P:
X4: 6-7
X1M: H-com
230 V
1
Only for
(heat pump convector)
2 core
X4: 6-7
X11M: 5-6
230 V
High pressure switch
Surge arrestor
Connector
Connector
Varistor
Connector
Terminal strip
Electronic expansion valve
Solenoid valve (4‑way valve)
Noise filter (ferrite core)
Noise filter
OPTIONAL PART
OPTIONAL PART
OPTIONAL PART
R2T External sensor
(floor or ambient)
A3P:
2 core
(3m included)
X1M: 1-3
signal
EJHA04AAV3 + NHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P556861-1A – 2019.05
Only for EKRTETS
4D115768A

Advertisement

Table of Contents
loading

Table of Contents