Code
[A.2.2.3]
[E‑07]
Domestic hot water tank:
▪ 0 (Type 1): EKHWS*D* or third-party
tank (see below).
▪ 4 (Type 5). EKHWP.
▪ 6 (Type 7) Third-party tank.
Range: 0~6
[A.2.2.A]
[D‑02]
In case a tank is installed, the outdoor
unit offers the possibility to connect a
field supplied domestic hot water pump
(On/OFF type). Depending on the
installation and configuration on the user
interface, we distinguish its functionality.
Not applicable for Switzerland.
In case of [E‑06]=1
▪ 0 (No): NOT installed
▪ 1 (Secondary
instant hot water when water is
tapped.
operation timing (weekly schedule
time) of the domestic hot water pump
when it should run. Control of this
pump is possible through the outdoor
unit.
▪ 2 (Disinf.
disinfection.
disinfection function of the domestic
hot water function is running. No
further settings are needed.
See also illustrations below.
INFORMATION
The tank can be heated via the gas boiler or heat pump.
NOTICE
If a domestic hot water pump for instant hot water is
present in the system ([D‑02]=1), scaling of the boiler heat
exchanger can occur faster due to more frequent domestic
hot water operation.
In case of [E‑06]=1
Domestic hot water pump installed for...
Instant hot water
a
b
c
e
f
d
a
Outdoor unit
b
Gas boiler
c
Tank
d
Cold water
e
Shower
f
Domestic hot water pump
g
Heater element
h
Non‑return valve
INFORMATION
The correct domestic hot water default settings become
only applicable when domestic hot water operation is
activated ([E‑05]=1).
Thermostats and external sensors
External room thermostat control is only applicable in case of
NHY2KOMB28+32AA gas boiler.
EJHA04AAV3 + NHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P556861-1A – 2019.05
Description
rtrn): Installed for
The
end-user
sets
the
shunt): Installed for
It
runs
when
the
Disinfection
a
b
c
f
g e
h d
#
Code
[A.2.2.4]
[C-05]
Contact type main
In external room thermostat control, the
contact type of the optional room
thermostat or heat pump convector for
the main leaving water temperature zone
must be set. See
guidelines" on
▪ 1 (Thermo
external room thermostat or heat
pump convector sends the heating
demand to the NHY2KOMB28+32AA
gas boiler (X4/6). Select this value in
case of a connection to the heat pump
convector (FWXV).
▪ 2 (H/C
external room thermostat sends a
heating demand and is connected to
the digital input (preserved for the
main leaving water temperature zone)
on
boiler (X4/6). Select this value in case
of
(EKRTWA) or wireless (EKRTR1)
room thermostat.
[A.2.2.B]
[C-08]
External sensor
When an optional external ambient
sensor is connected, the type of the
sensor must be set. See
guidelines" on
▪ 0 (No): NOT installed. The thermistor
in the user interface and in the heat
pump
measurement.
▪ 1 (Outdoor
outdoor
measure
temperature.
functionality, the temperature sensor
in the outdoor unit is still used.
▪ 2 (Room sensor): NOT applicable.
Savings mode
The user can choose whether switching between operation modes is
either economically or ecologically optimised. Set to Economical,
the system will in all operating conditions select the energy source
(gas or electricity) based on energy prices, resulting in a
minimisation of energy costs. Set to Ecological, the heat source
will be selected based on ecological parameters, resulting in a
minimisation of primary energy consumption.
#
Code
[A.6.7]
[7‑04]
Defines whether switching between
operation modes is either economically
or ecologically optimised.
▪ 0 (Economical): reduction of energy
costs
▪ 1 (Ecological): reduction of primary
energy
necessarily energy costs
Primary energy factor
The primary energy factor indicates how many units of primary
energy (natural gas, crude oil, or other fossil fuels, prior to
undergoing any human-made conversions or transformations) are
needed to obtain 1 unit of a certain (secondary) energy source, such
as electricity. The primary energy factor for natural gas is 1.
10 Configuration
Description
"7 Application
page 17.
ON/OFF): The connected
request): The connected
the
NHY2KOMB28+32AA
gas
connection
with
the
wired
"7 Application
page 17.
module
are
used
for
sensor): Installed. The
sensor
will
be
used
the
outdoor
ambient
Remark:
For
some
Description
consumption,
but
not