Field settings table
Breadcrumb
Field code
Setting name
A.8
[C-04]
Bivalent hysteresis temperature.
A.8
[C-05]
What is the thermo request contact type for the main zone?
A.8
[C-06]
--
A.8
[C-07]
What is the unit control method in space operation?
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
--
A.8
[C-0A]
Indoor quick heat-up function
A.8
[C-0B]
Is Delta T control enabled?
A.8
[C-0C]
High electricity price decimal (Do not use)
A.8
[C-0D]
Medium electricity price decimal (Do not use)
A.8
[C-0E]
Low electricity price decimal (Do not use)
A.8
[D-00]
--
A.8
[D-01]
--
Which type of DHW pump is installed?
A.8
[D-02]
A.8
[D-03]
Leaving water temperature compensation around 0°C.
A.8
[D-04]
--
A.8
[D-05]
--
A.8
[D-07]
--
A.8
[D-08]
--
A.8
[D-09]
--
A.8
[D-0A]
Is an external gas meter used for power measurement?
A.8
[D-0B]
--
A.8
[D-0C]
What is the high electricity price (Do not use)
A.8
[D-0D]
What is the medium electricity price (Do not use)
A.8
[D-0E]
What is the low electricity price (Do not use)
A.8
[E-00]
Which type of unit is installed?
A.8
[E-01]
Which type of compressor is installed?
A.8
[E-02]
What is the indoor unit software type?
A.8
[E-03]
--
A.8
[E-04]
Is the power saving function available on the outdoor unit?
A.8
[E-05]
Can the system prepare domestic hot water?
A.8
[E-06]
Is a DHW tank installed in the system?
A.8
[E-07]
What kind of DHW tank is installed?
A.8
[E-08]
Power saving function for outdoor unit.
A.8
[E-09]
--
A.8
[E-0A]
--
A.8
[E-0B]
--
A.8
[E-0C]
--
A.8
[E-0D]
Is the system filled with glycol?
A.8
[F-00]
Pump operation allowed outside range.
A.8
[F-01]
--
A.8
[F-02]
Bottom plate heater ON temperature.
A.8
[F-03]
Bottom plate heater hysteresis.
A.8
[F-04]
What is the configuration of electric heaters?
A.8
[F-05]
--
A.8
[F-09]
--
A.8
[F-0A]
--
A.8
[F-0B]
--
A.8
[F-0D]
What is the pump operation mode?
4P564438-1 - 2018.12
Range, step
Default value
R/W
2~10°C, step 1°C
3°C
R/W
1: Thermo ON/OFF
2: C/H request
1
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: No
1: Outdoor sensor
2: Room sensor
0
R/W
0: Disable
1: Enable
0: Disable
1: Enable
R/W
0~7
4
R/W
0~7
4
R/W
0~7
4
0
0
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
0
1
0
0
0
R/W
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
2
R/W
0~49
20
R/W
0~49
20
R/W
0~49
15
R/O
0~6
6: Monobloc Hybrid
R/O
0: 08
R/O
0: Type 1
1: Type2
0
R/O
1: Yes
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0~6
0: Type1(EKHWS*D* )
4: Type 5(EKHWP*)
6: Type 7(Third party)
R/W
0: Disabled
1: Enabled
0
0
0
0
R/W
0: No
1: Yes
R/W
0: Disabled
1: Enabled
20°C
R/W
3~10°C, step: 1°C
3°C
R/W
2~5°C, step: 1°C
5°C
R/W
0: No
1: BPH only
2: BPH+DTH Type1
3: BPH+DTH Type2
4: BPH+DTH Type3
0
0
0
0
R/W
0: Continuous
1: Sample
2: Request
Installer setting at variance with
default value