Field settings table
Breadcrumb
Field code
Setting name
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.5
[8-05]
Modulated LWT
A.3.1.1.7
[2-0C]
Emitter type
└────────────────── Delta T source
A.3.1.3
[1-0B]
Heating
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
A.3.2.1.2
[3-06]
Room temp. range
A.3.2.2
[2-0A]
Room temp. offset
A.3.2.4
Room temp. step
└─ Operation range
A.3.3.1
[4-02]
Space heating OFF temp
└─ Domestic hot water (DHW)
└─ Type
A.4.1
[6-0D]
└─ Disinfection
A.4.4.1
[2-01]
Disinfection
A.4.4.2
[2-00]
Operation day
A.4.4.3
[2-02]
Start time
A.4.4.4
[2-03]
Temperature target
A.4.4.5
[2-04]
Duration
└─ Maximum setpoint
A.4.5
[6-0E]
└─ SP mode
A.4.6
└─ Weather dependent curve
A.4.7
[0-0B]
Weather-dependent curve
A.4.7
[0-0C]
Weather-dependent curve
A.4.7
[0-0D]
Weather-dependent curve
A.4.7
[0-0E]
Weather-dependent curve
└─ Heat sources
└─ Boiler
A.5.2.2
[5-01]
Equilibrium temp.
A.5.2.3
[8-0E]
Boiler only ambient temp.
└─ System operation
└─ Auto restart
A.6.1
[3-00]
└─ Pwr consumpt. Control
A.6.3.1
[4-08]
Mode
A.6.3.2
[4-09]
Type
A.6.3.3
[5-05]
Amp. value
A.6.3.4
[5-09]
kW value
└─ Averaging time
A.6.4
[1-0A]
└─ Ext amb. sensor offset
A.6.5
[2-0B]
└─ Savings mode
A.6.7
[7-04]
└─ Emergency
A.6.C
└─ Disable protective Function
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (heating)
Maximum temp (heating)
DHW setpoint for high ambient temp. for DHW
WD curve.
DHW setpoint for low ambient temp. for DHW
WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Range, step
Default value
R/W
0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~80°C, step: 1°C
55°C
R/W
0: No
1: Yes
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
R/W
3~66°C, step: 1°C
10°C
R/W
12~18°C, step: A.3.2.4
12°C
R/W
18~30°C, step: A.3.2.4
30°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: 1°C
1: 0,5°C
R/W
14~35°C, step: 1°C
35°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
0: No
1: Yes
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0~23 hour, step: 1 hour
23
R/W
fixed value
60°C
R/W
40~60 min, step: 5 min
40 min
R/W
[E-06]=1
[E-07] ≠ 6: 40~75°C, step: 1°C, 75°C
[E-07] = 6: 40~60°C, step: 1°C, 60°C
[E-06]=0
40~65°C, step: 1°C, 65°C
R/W
0: Fixed
1: Weather dep.
R/W
35~[6-0E]°C, step: 1°C
55°C
R/W
45~[6-0E]°C, step: 1°C
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
-15~35°C, step: 1°C
5°C
R/W
-15~25°C, step: 1°C
-5°C
R/W
0: No
1: Yes
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: Economical
1: Ecological
R/W
0: Manual
1: Automatic
3/6
Installer setting at variance with
default value
Date
Value