5.1 Refrigerant

BEWARE
The appliance contains in the refrigerant circuit the
refrigerant isobutane (R600a), a highly environ -
mentally compatible natural gas that is inflammable.
While transporting and installing the appliance ensure
that no parts of the refrigerant circuit are damaged.
Procedure if the refrigerant circuit is damaged:
• avoid open fire and ignition sources at all costs
• ensure that the room in which the appliance is located is well ventilated
6

Installation

6.1 Positioning

The appliance should be located in a well ventilated and dry room.
The ambient temperature affects the power consumption and correct
function of the appliance.
Sufficient air circulation on the rear wall and upper edge of the appliance
must be guaranteed. For optimal ventilation of the appliance the minimum
ventilation crossections must be observed: i.e. position the refrigerator at
least 100 mm away from the wall, and furthermore a space of 20 mm must
be left to the right and to the left, and 300 mm at the top. If you wish to place
the appliance on a carpet, ensure that you use a solid and smooth base.