7
Operation and service
Load profile (thermal cycling, also number of starts/stops, emergency shutdowns)
Gas inlet temperature
Frequency and execution of turbine and compressor cleaning
Turbocharger specification.
For bearing parts
Lubricating oil quality (oil filtering, oil condition, oil monitoring)
Load profile (speed, pressure conditions, temperature)
Imbalance of the rotor (degree of contamination)
7.4
Stopping the engine
Stopping the engine
In the turbocharger, the heat from the lubricating oil that continues to circula-
te must be dissipated.
CAUTION
Let the engine continue to run at idling speed for 5 to 10 minutes before
stopping it.
Observe the oil pressure specified for engine idling (see Table 5).
Post-lubrication
Post-lubrication is not required and not recommended for water-cooled bearing casings.
For oil-cooled bearing casings, post-lubrication is mandatory for 20 minutes if the turbine
inlet temperature (t
– 550 °C with insulated casing
– 600 °C with non-insulated casing
At temperatures below the specified values, post-lubrication for 10 minutes is recom-
mended.
Observe the oil pressure specified for post-lubrication (see Table 5).
© Copyright 2013 ABB. All rights reserved.
) exceeds the following values when the engine is stopped: