Operation and service
Suggestion for noise insulation, bellows
Figure 23
A
Compressor casing
B
Bellows
C
Charge air duct / scavenging air duct
7.2

Service work

Service work includes visual controls, monitoring, measuring and inspection as well as func-
tion checks. Service work enables to detect and rectify changes to the turbocharger and en-
sures full operability of the turbocharger.
Service intervals
Service work on the turbocharger that is omitted or performed too late can
cause excessive contamination and wear as well as operating failures.
CAUTION
Carry out the service work at the specified time intervals.
© Copyright 2013 ABB. All rights reserved.
D
Insulating cushion
E
Insulation mat (at least 15 mm)
F
Sheet metal cover