Panasonic PT-FX500 Operating Instructions Manual page 131

Table of Contents

Advertisement

Chapter 6 Maintenance — Lamp/temperature/filter indicators
Temperature indicator <TEMP>
Indicator status
Status
Internal temperature is high (warning).
f Is the air intake/exhaust port blocked?
Cause
f Is the room temperature high?
f Is the filter indicator <FILTER> lit?
f Remove any objects that are blocking the air intake/exhaust port.
f Install the projector in a location with the operating environment temperature
between 0 °C (32 °F) and 40 °C (104 °F)
Solution
f Do not install the projector at high altitudes of 2 700 m (8 858') or higher
above sea level.
f Clean or replace the air filter unit. ( x page 132)
*1 When using the projector at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea level), the operating environment
temperature should be between 0 °C (32 °F) and 35 °C (95 °F).
Note
f If the temperature indicator <TEMP> is still lit or blinking after taking the preceding measures, ask your dealer for repair.
f If the [PROJECTOR SETUP] menu → [LAMP POWER] is set to [NORMAL], [LAMP POWER] changes to [ECO] forcibly to protect the
projector when the operating environment temperature becomes 35 °C (95 °F) or higher (30 °C (86 °F) or higher when using the projector at
high altitudes).
Filter indicator <FILTER>
Indicator status
The filter is clogged.
Status
The temperature inside or outside the projector is abnormally high.
f Is the air filter unit dirty?
Cause
f Clean or replace the air filter unit.
Solution
( x page 132)
Note
f If the filter indicator <FILTER> is still lit or blinking after taking the preceding measures, ask your dealer for repair.
f If the air filter case is not attached when the projector is switched on, the filter indicator <FILTER> blinks in red.
Lighting in red
Internal temperature is high (standby
status).
Lighting in red
f Is the air intake/exhaust port
blocked?
f Remove any objects that are
blocking the air intake/exhaust port.
Blinking in red
(2 times)
*1
.
Blinking in red
(3 times)
The cooling fan has stopped.
f Turn the <MAIN POWER> switch to
<OFF> ( x page 46), and consult
your dealer.
Blinking in red
The air filter unit is not attached.
f Is the air filter unit attached?
f Attach the air filter unit.
ENGLISH - 131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-fz570uPt-fz570Pt-fx500uPt-fw530Pt-fw530u

Table of Contents