8
FINE LIMIT SWITCH ADJUSTMENT
...
During the following steps, the motor protector may
open. Wait about 20 minutes for protector to reset.
1. Adjusting the "OPEN" limit switch (Fig. 8-1).
• Run door to open position by pushing wall control.
• Locate curved "OPEN" limit adjustment slot on
24
back of power head.
• Look into slot for pinion screw.
• Insert a screwdriver and turn pinion screw.
– clockwise to open more.
– counterclockwise to open less.
2. Test door operator. Use wall control to run
door open and close.
3. Repeat step as necessary to properly set
"OPEN" limit switch.
4. Adjust the "CLOSE" limit switch (Fig. 8-1).
• Run door fully closed by pushing wall control.
• Locate curved "CLOSE" limit adjustment slot on
back of power head.
• Look into slot for pinion screw.
• Insert a screwdriver and turn pinion screw.
– counterclockwise to close more.
– clockwise to close less.
5. Test door operator. Use wall control to run door
open and close
6. Repeat step as necessary to properly set
"CLOSE" limit switch
7. Perform CONTACT REVERSE
9

REMOTE CONTROLS

...
Moving door can cause serious injury or death
• Keep people clear of opening while door is moving.
• Do Not allow children to play with remote controls.
If safety reverse does not work properly:
• Close door and disconnect operator using
emergency release.
• Do not use door operator or remote controls
• Refer to door and door operator owner's
Manuals before attempting any repairs
NOTE: Factory sets different codes for each remote
control.
Remote controls will not work if STB's malfunction
When programming remote control keep at least 24
inches away from antenna.
1. Program one-button remote (Fig. 9-1)
• Locate learn code button and learn indicator on
power head.
– Remove lens cover on back of power head.
• Press and release learn code button on
power head.
– LED on power head blinks 2 times per second.
WARNING
(continued on next page)
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
MORE
CLOSE
LIMIT ADJUSTMENT
CLOSE
Fig. 8-1
Actual picture may vary by model
Complete with
Battery
One-Button Remote Control*
1
2
NEC
CLASS 2
3
4
MORE
MORE
PUSH
CLOSE
OPEN
TO SET
LIMITS
LIMIT ADJUSTMENT
STEALTH
Fig. 9-1
* Remotes vary depending on model. Your operator will
have one or the other.
MORE
OPEN
1
2
NEC
CLASS 2
3
4
MORE
MORE
PUSH
OPEN
TO SET
LIMITS
LIMIT ADJUSTMENT
Multi-Button Remote Control*
NEC
CLASS 2
PUSH
BUTTON
COM
NOTE:
SAFETY
USE ONLY WITH
BEAM
SERIES II CONTROLS
DO NOT
PUSH
LIMIT SET
UNLESS
DOOR IS
ATTACHED
LIMIT
SET
CLOSE
OPEN
OPEN
FORCE
MORE
MORE
MORE
CLOSE
FORCE
FORCE
RADIO
SIGNAL
CLOSE
OPEN
LEARN
LIMIT ADJUSTMENT
CODE
U.S. Patent No. 5,243,784
5,221,869
PRO-MAX
1
2
3
4
5
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmx-ic bStealthPmx-ic b series

Table of Contents