Download Print this page

System Specifications; Amplifier Section - Genelec 1036A Datasheet

Control room monitoring system
Hide thumbs Also See for 1036A:

Advertisement

SYSTEM
SPECIFICATIONS
Lower cut-off frequency,
-3 dB:
-6 dB: < 17,5 Hz
Upper cut-off frequency, -3 dB: > 22 kHz
Free field frequency response
of system:
21 Hz - 20 kHz ( 2.5 dB)
Maximum short term sine wave
acoustic output on axis
in half space, averaged from
100 Hz to 3 kHz:
@ 1m
> 131 dB SPL
Maximum long term RMS acoustic
output in same conditions with IEC-weighted
noise (limited by driver unit protection cir-
cuit):
@ 1m
> 126 dB SPL
Maximum peak acoustic output per
pair @ 2 m from the engineer
with music material:
> 136 dB
Self generated noise level in
free field @ 2m on axis:
< 20 dBA
Harmonic distortion at 100 dB SPL
@ 1m on axis:
Freq:
50...200 Hz
200...4k Hz
> 4 kHz
Drivers:
Bass
2 x 460 mm (18") cone
Mid
2 x 120 mm
Treble 1 x 25 mm
compression driver
Weight:
Speaker
182 kg
Amplifier
71 kg
Speaker dimensions (Horizontal mounting):
Height
960 mm
Width
1180 mm
Depth
650 mm
Amplifier dimensions:
Height
755 mm
Width
483 mm
Depth
370 mm
All data subject to change without prior notice.
Genelec Oy, Olvitie 5
FIN - 74100 IISALMI, FINLAND
Phone:
+358 - 17 - 813 311
Fax:
+358 - 17 - 812 267
E-mail:
genelec@genelec.com
Web:
http://www.genelec.com
AMPLIFIER
SECTION
< 19 Hz
Bass amplifier output power with an 8 Ohm
load:
Mid amplifier output power with a 4 Ohm
load:
Treble amplifier output power with an 8
Ohm load:
Long term output power is limited by driver
unit protection circuitry.
Slew rate :
Amplifier system distortion at
nominal output:
Signal to Noise ratio, referred to full output:
<1%
<0.5%
<3%
Mains voltage: 100/110/115/220/230/240V
Voltage operating range at
(5") cone
230V setting:
(1")
115V setting:
Power consumption:
(401 lb)
(156 lb)
(37
3
/
")
4
(46
1
/
")
2
1
(25
/
")
2
3
(29
/
")
4
(19")
(14
9
/
")
16
Genelec Document BBA36001a COPYRIGHT GENELEC OY 8.2000
CROSSOVER
SECTION
Input connector: XLR female
Short term 2 x 1100 W
Input impedance:
Short term 600 W
Input level for 110 dB SPL output @ 1m:
Input level for maximum short term output of
Short term 300 W
131 dB SPL @ 1m:
Subsonic filter below 18 Hz :
100 V/ s
Ultrasonic filter above 22 kHz:
THD
<0.05%
Crossover frequencies:
SMPTE-IM
<0.05%
CCIF-IM
<0.05%
DIM 100
<0.05%
Crossover acoustical slopes:
Bass
>101 dB
Level control operating range in 1 dB steps:
Mid
>105 dB
Treble
>106 dB
Bass roll-off control in 2 dB steps:
219 - 241 V ( 5%)
109 - 121 V ( 5%)
Bass tilt control operating
range in 2 dB steps:
Idle
150 W
Full output
3500 W
Treble roll-off control operating
range in 1 dB steps:
The 'CAL' position is with all tone controls
set to 'off' and input sensitivity control to
maximum and corresponds to a maximally
flat free field response.
1036A
pin 1 gnd
pin 2 +
pin 3 -
10 kOhm balanced
variable from +15 to -5 dBu
variable from +36 to +16 dBu
18 dB/octave
12 dB/octave
Bass/Mid
400 Hz
Mid/Treble
3.5 kHz
>24 dB/octave
Bass
from 0 to -6 dB & MUTE
Mid
from 0 to -6 dB & MUTE
Treble
from 0 to -6 dB & MUTE
from 0 to -8 dB @ 30 Hz
from 0 to -8 dB @ 50 Hz
from +1 to -3 dB @15 kHz
Genelec Inc, 7 Tech Circle
Natick, MA 01760, USA
Phone:
+1 - 508 - 652 - 0900
Fax:
+1 - 508 - 652 - 0909
E-mail:
genelec.usa@genelec.com

Advertisement

loading