Fireplace Installation
circulation beneath the fire-
place insert is provided by 4
felt feet.
Do not install the fireplace
insert directly on carpet or
similar surfaces which may
restrict air circulation.
CAUTION:
fireplace in a carpeted area, place
a one-piece, solid, flat surface un-
der the fireplace. Ensure that all
feet rest securely on this surface.
!
NOTE: The dimensions of the
firebox are:
Width
24.1in.
PF2325
(612mm)
31.3in.
PF3033
(796mm)
Mantel Installation
Install the fireplace into the
mantel (refer to mantel assembly
instructions).
!
IMPORTANT: Install the man-
tel so that it is a minimum of ⅜ in.
(10 mm) off of the wall to ensure
adequate air flow.
!
IMPORTANT: If not using a
Dimplex mantel, the fireplace
must be installed in an enclosure
with the following minimum inter-
nal/opening dimensions - Figure 2.
If installing the
Height
Depth
18.1in.
8.9in.
(459mm)
(225mm)
22.5in.
8.9in.
(573mm)
(226mm)
Custom Mantel Construction
1. Frame an opening of, see
dimensions in Figure 2:
!
NOTE:
On elevated instal-
lations, the bottom edge and ½
in. (13 mm) up either side will
be easily visible after installa-
tion (Figure 2). This area should
be finished in a manner that is
visually appealing and does not
restrict air flow to the unit.
Figure 2
A
25.0in.
PF2325
(635mm)
32.1in.
PF3033
(816mm)
!
NOTE: The fireplace needs to be
installed to ensure 35 in
intake air, into the back of the unit, on
a continuous basis.
B
C
A
B
C
18.5in.
10.0in.
(470mm)
(254mm)
22.8in.
10.0in.
(579mm)
(254mm)
(226 cm
) of
2
2
7