PRODUCT IDENTIFICATION
Each pump has a Model Code stamped on its
nameplate. See Figure 1 for the location of the
Model Code.
Model Code
Installation, Start-Up, Operating Instructions, Parts Pages, Repair Procedures
PVR1-
6B10 - RM - 0 - 1 - I
SAVAGE M N U. S. A 55378
RATI NGS
r
r pm
m
l
/ r
v
I N
3
/ r
p
ps i
p
bar
Figure 1
Form No. 253585 Rev. 04/19
SERVICE MANUAL
PVR1 Manifold Series Pump
This service manual applies to products with Ordering
Codes like the sample in Figure 2.
PVR1- _ _ _ _ - RM - _ - _ _ - I
Basic Pump
Pump Size
Pressure
Seal Type
Mechanical Options
Design Letter

INSTALLATION

NOTE THESE CHANGES: Design Series
"A" thru "G" used a #406 woodruff key
nominally 1/8 inch (3.2 mm) wide. Design
Series "H" and later use a common 3/16 x 3/16 x 1
inch square key. When replacing older pumps with a
newer one, it will be necessary to either install a new
coupling half with a 3/16 inch keyway or machine the
existing keyway. Also, the pressure adjustment screw
is 3/4 inch (19.1 mm) longer. Check dimensions of
existing installation to make sure there is sufficient
clearance for the adjustment screw.

PUMP DRIVE AND MOUNTING

When mounting the pump and motor, care must be
taken to align the pump and motor shafts within .003
T.I.R. Direct inline through a jaw type/flexible web
coupling is recommended for all Continental pumps.
Tire-type flexing elements and chain-type drives are
not recommended. With belt drives, please consult
factory.
To avoid axial and radical end loading of the pump
shaft, do not couple the pump and motor shafts
rigidly. Allow freedom at the coupling for the two
shafts to ride independently.
To prevent end loading, the space between the pump
and motor shaft ends should be 1/2 inch (12.7 mm)
for PVR1 pumps, or as the coupling manufacturer
specifies.
"I" Design Series
Figure 2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVR1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Continental Hydraulics PVR1 Series

  • Page 1 SERVICE MANUAL PVR1 Manifold Series Pump Installation, Start-Up, Operating Instructions, Parts Pages, Repair Procedures “I” Design Series This service manual applies to products with Ordering Codes like the sample in Figure 2. PVR1- _ _ _ _ - RM - _ - _ _ - I Basic Pump Pump Size Pressure...
  • Page 2 PIPING AND RESERVOIR drain line should be protected with an 8 psi (0.55 bar) The pump should be mounted with a minimum maximum relief valve in parallel with the heat number of elbows or fittings. The pump suction exchanger. No other return lines should be connected should be at least one (1) inch (25.4 mm) tube/pipe in common with the case drain return.
  • Page 3 The pressure adjusting screw is located at the end Stop adjusting the volume screw when pressure face of the compensator chamber. See parts page begins to drop. See Sales Catalog for complete item number 30. The adjusting screw has a right pump performance specifications.
  • Page 4 PVR1 PARTS DRAWINGS 4B Only For PVR1-6B, Code 13 Tandem Mounting Only Form No. 253585 Rev. 04/19...
  • Page 5 PVR1 PARTS LIST 163797 Bearing Bushing ITEM CODE PART DESCRIPTION REQ’D ITEM CODE PART DESCRIPTION 550173 Pump Body REQ’D 508943 Cover 126225 Key (Add 1 - Code 13; 6B) 1 6B; Code 13 550833 Cover 004223 Roll Pin 407929 Rotor Shaft 130795 Lip Seal (Add 1 - Code 13;...
  • Page 6 PVR1 PUMP REPAIR PROCEDURES 11. It is unlikely that further disassembly will be necessary in order to perform routine maintenance on the pump. DISASSEMBLY PROCEDURE NOTE: Disassembling the pump to REASSEMBLY PROCEDURE change components, or for any other 1. Clean and inspect parts to determine which parts reason, may void the warranty.
  • Page 7 9. Install the o-ring (15) into the thrust plate (5) and 12. Torque the cover bolts to 50 lbs-ft ±10 lbs-ft. The the square teflon seal ring (13) on top of it. Stretch shaft should turn by hand when assembly is the larger soft seal ring slightly so it clings to the OD complete.
  • Page 8 5505 West 123rd Street Savage, MN 55378 Phone: (952) 895-6400 Fax: (952) 895-6444 www.continentalhydraulics.com Because Continental Hydraulics is continually improving its’ products, specifications and appearance are subject to change without notice. Form No. 253585 Rev. 04/19 © 2008, Continental Hydraulics. Printed in U.S.A...