Quick Links

CAUTION - Before performing any service
operation on any pump, be sure that all
pressure has been relieved from BOTH
SIDES of the system.
CAUTION - Before performing any service
operation on any pump, disconnect or lock
off power supply.
CAUTION - Before starting pump, be sure
that any resulting machine function will not
endanger persons or equipment.
PRODUCT IDENTIFICATION
Each pump has an Ordering Code stamped on its
nameplate. See below for the location of the Ordering
Code.
SERVICE MANUAL
PVR15-30B-Flanged Series Pump
Installation, Startup, Operating Instructions, Parts Pages, Repair Procedures
This service manual applies to products with Ordering
Codes like the sample below.
PVR15 - 30B15 - RF - _ - 5 - _ _ _ _ _ - D
Basic Pump
Pump Size
& Pressure
Rotation & Mounting
Seal Type
Mechanical Options
Control Options
Design Letter
INSTALLATION
PUMP DRIVE AND MOUNTING
When mounting the pump and motor, care must be
taken to align the pump and motor shafts within .003
T.I.R. (0.076 mm) direct inline through a jaw type/
flexible web coupling. This is recommended for all
pumps. Tire-type flexing elements and chain-type
drives are not recommended. With belt drives, please
consult factory.
To avoid axial and radical end loading of the pump
shaft, do not couple the pump and motor shafts
rigidly. Allow freedom at the coupling for the two
shafts to ride independently.
To prevent end loading, the space between the pump
and motor shaft ends should be 3/4 inch (19.05 mm)
for PVR15 pumps, or as the coupling manufacturer
specifies.
PIPING AND RESERVOIR
The pump should be mounted with a minimum
number of elbows or fittings. The pump suction
should be at least 1-1/4 inch (31.75 mm) tube/pipe for
PVR15 pumps.
For any system and combination of piping except
High Water Based Fluids (HWBF), the vacuum at the
pump inlet must not exceed seven inches of Mercury,
(5 inch Hg. for fire resistant fluids). HWBF Pumps are
to have a positive inlet head in the range of 0.5-inch
Hg. to 20 inch Hg.
Form No. 265283
Rev. 07/08
"D" Design Series
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVR15-30B-Flanged Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Continental Hydraulics PVR15-30B-Flanged Series

  • Page 1 SERVICE MANUAL PVR15-30B-Flanged Series Pump Installation, Startup, Operating Instructions, Parts Pages, Repair Procedures “D” Design Series This service manual applies to products with Ordering Codes like the sample below. PVR15 - 30B15 - RF - _ - 5 - _ _ _ _ _ - D...
  • Page 2: Start-Up Procedures

    Installation (Continued...) Piping should be done with pickled pipe or seamless allow free flow from the pump back to tank or connect tubing free of dirt and scale. Do not use galvanized the pump outlet line directly to tank. Jog the motor on or other pipe that tends to flake off.
  • Page 3: Adjustment Procedures

    Operation (Continued...) A pressure gauge located at the pump must be used 3. See Pressure and Volume Adjustment Sensitivity when making adjustment to insure the pressure chart below. settings do not exceed limits specified for the particular pump of maximum system pressure. 4.
  • Page 4: Part Description

    PVR15-30B PARTS LIST ITEM PART QTY. ITEM CODE PART DESCRIPTION QTY. CODE DESCRIPTION REQ. REQ. 550360 Pump Body 122975 Shim (.010) A.R. 550629 Cover 301737 Handwheel 18, 24, 25 550630 Cover 004262 Spring Pin 2118, 2218 550631 Cover Valve Refer to Valve Escutcheon 21, 22, 31 550632 Cover 17,18**,2500,...
  • Page 5 PVR15-30B PARTS DRAWING See Page 6 for Control Options. PVR15-30B PARTS DRAWING Codes 12, 21, 22, 31 Tandem Mounting Form No. 265283 Rev. 07/08...
  • Page 6 PVR15-30B PARTS DRAWING Control Options Code 17 Code 2400 Dual Pressure Control Without Integral Valve Dual Volume Control Without Integral Valve Code 18** Code 24** Dual Pressure Control With Integral Valve Dual Volume Control With Integral Valve 50, 69, 70 99, 51 69, 70, 50 99, 56...
  • Page 7: Disassembly Procedure

    PVR15-30B PUMP REPAIR PROCEDURES the pump. REASSEMBLY PROCEDURE DISASSEMBLY PROCEDURE 1. Clean and inspect parts to determine which parts NOTE: Disassembling a pump to change are worn enough to require replacement. components, or for any other reason, may void the warranty.
  • Page 8 5505 West 123rd St. Savage, MN 55378 Phone: (952) 895-6400 Fax: (952) 895-6444 www.continentalhydraulics.com Because Continental Hydraulics is continually improving its’ products, specifications and appearance are subject to change without notice. Form No. 265283 Rev. 07/08 © 2008, Continental Hydraulics. Printed in U.S.A...

This manual is also suitable for:

D design seriesPvr15-015b15-rf-0-5-fPvr15-manifold seriesJ design seriesPvr15-15b1l-rm-o-1-j

Table of Contents