ELECTRICAL INSTRUCTIONS
A. Before your new unit is connected to a power supply,
check the incoming voltage with a voltmeter. If anything
less than 100% of the rated voltage for operation is noted,
correct immediately.
B. All units are equipped with a service cord, and must be
powered at proper operating voltage at all times. Refer to
cabinet data plate for this voltage.
TRUE requires that a sole use circuit be dedicated for the unit.
Failure to do so voids warranty.
SEALING CABINET TO FLOOR
Step 1 - Position Cabinet
Allow one inch between the wall and rear of the GDM
refrigerator to assure proper ventilation. For GDM freezers
3 inches between the wall and rear of the cabinet will assure
proper ventilation.
Step 2 - Level Cabinet
Cabinet should be level, side to side and front to back. Place a
carpenter's level in the interior floor in four places:
A. Position level in the inside floor of the unit near the
doors. (Level should be parallel to cabinet front). Level
cabinet.
B. Position level at the inside rear of cabinet. (Again level
should be placed parallel to cabinet back).
C. Perform similar procedures to steps a & b by placing the
level on inside floor (left and right sides - parallel to the
depth of the cooler). Level cabinet.
Step 3
Draw an outline on the base on the floor.
Step 4
Raise and block the front side of the cabinet.
Step 5
Apply a bead of "NSF Approved Sealant", (see list below), To
floor on half inch inside the outline drawn. The bead must
be heavy enough to seal the entire cabinet surface when it is
down on the sealant.
11
INSTALLATION / OPERATION INSTRUCTIONS
............ www.truemfg.com ............
WARNING
Compressor warranties are void if compressor burns out due to
low voltage.
WARNING
Power supply cord ground should not be removed!
WARNING
Do not use electrical appliances inside the food storage
compartments of the appliances unless they are of the
type recommended by the manufacturer.
NOTE
To reference wiring diagram - Remove front louvered grill, wiring
diagram is positioned on the inside cabinet wall.
Step 6
Raise and block the rear of the cabinet.
Step 7
Apply sealant on floor as outline in Step 5. on other three
sides.
Step 8
Examine to see that cabinet is sealed to floor around entire
perimeter.
Note
Asphalt floors are very susceptible to chemical attack.
A layer of tape on the floor prior to applying the sealant
will protect the floor.
NSF Approved Sealants:
1. Minnesota Mining #ECU800 Caulk
2. Minnesota Mining #ECU2185 Caulk
3. Minnesota Mining #ECU1055 Bead
4. Minnesota Mining #ECU1202 Bead
5. Armstrong Cork - Rubber Caulk
6. Products Research Co. #5000 Rubber Caulk
7. G.E. Silicone Sealer
8. Dow Corning Silicone Sealer