Alarm Input And Output Port; Alarm Output Port; Alarm Relay Specifications - Dahua NVR6032K User Manual

Table of Contents

Advertisement

5-ON C,6-ON C,
7-ON C,8-ON C
A/B

2.3.2 Alarm input and output port

Please refer to the following sheet for more information.
Grounding alarm inputs. Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide external power to the
alarm detector).
Please parallel connect the Ground of the NVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the NVR alarm input(ALARM)
Use the same ground with that of NVR if you use external power to the alarm device.

2.3.3 Alarm Output Port

Provide power to peripheral alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
RS485 A/B cable is for the A/B cable of the PTZ decoder.

2.3.4 Alarm relay specifications

Model:
Material of the
touch
Rating
(Resistance
Load)
Insulation
GND cable.
The A/B cable to control the RS485 devices. It is to connect to
control devices such as PTZ dome camera. 120Ω should be parallel
connected between A, B lines on the far end to reduce reflection and
guarantee the signal quality.
JRC-27F
Silver
Rated switch capacity
Maximum switch power
Maximum switch voltage
Maximum switch currency
Between touches with same
polarity
Between touches with different
polarity
Between touch and winding
Figure 2-5
30VDC 2A, 125VAC 1A
125VA 160W
250VAC, 220VDC
1A
1000VAC 1minute
1000VAC 1minute
1000VAC 1minute
7