Many problems have a simple cause and a correspondingly simple solution. The following section describes a few
difficulties you may encounter, and the measures you need to take to cure them. If you find it impossible to solve a
problem with the help of these notes please disconnect the unit from the mains and ask your authorised specialist
dealer for advice.
Device does not switch on
Fluctuating sound.
Unwanted hum
46
Trouble shooting
Cause:
Mains lead not connected correctly.
Remedy:
Check connection, push plug in firmly.
Cause 1:
Bearing not oiled sufficiently.
Remedy:
Oil the bearing: see section entitled 'Fitting the platter'.
Cause 2:
Drive belt worn or exhausted.
Remedy:
Replace drive belt.
Cause 3:
Drive belt oily.
Remedy:
Clean drive belt, pulleys and / or platter with methylated spirit on a cloth.
Cause:
The G 2000 R or a device connected to it is not earthed.
Remedy:
Connect a separate chassis earth wire (G 2000 R: earth terminal 'GND' to earth
clamp on the machine to which it is connected).