Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 3 of 14 2. Safety 2.1 Intended Use The loggers EB-Logg 80K and EB-Logg 80KH are especially designed for long-time monitoring of temperatures. The combination of low power consumption with high battery capacity ensure a long record- ing time.
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 4 of 14 2.4 Safety guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 5 of 14 3. Product description 3.1 Required accessory The logger is configured, started and read-out via the EASYBus-interface. Therefore the following accessories are required: Level converter - RS232 <> EASYBus (i.e. EBW 1, EBW 64, EBW 240) - USB <>...
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 6 of 14 4. Display and control elements 4.1 Display Main display Secondary display Display element for max / min Logg: indicates that logger is recording ...
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 7 of 14 6. Operation 6.1 Operating possibilities at the device - display selection Function Procedure Push button shortly The max-value is displayed for 4 seconds. (The max-value display function is signalled by the display ele- Display max value ment “MAX”).
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 8 of 14 Push button for about 5 seconds. The main display shows “HoLd”. The secondary display shows “no”. To stop recording select “YES” with the arrow key (button ) and verify with Stop recording Note: If no key is pressed for more than 2 min, the menu is quit without saving.
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 9 of 14 8. Operating displays The logger provides two LCD-displays: 7 mm (main display) and 5.8 mm (secondary display). 8.1 Measured value display The LCD mainly displays the measured values: MEASURED VALUE DISPLAY a) main display: temperature [°C] sec.
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 10 of 14 8.3 System messages BATTERY • display of the BAT-arrow left hand down: The battery is almost spent and needs to be replaced as soon as possible. The data recording is still active. •...
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 13 of 14 11. Frequently asked questions [FAQ] Problem: The logger cannot be stopped via keys. “Logger stop via buttons disabled” has been activated at the configu- Possible reason: ration of the logger. Deactivate this function by means of GSOFT 40K (at tab „settings“). Remedy: Problem: The logger cannot be stopped both via keys and GSOFT 40K.
Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 14 of 14 12. Device options Additional information’s for options of the EB-Logg 80K… . 12.1 AFK, detachable sensor cable For the “AFK” option, the Pt1000 is connected via a 4-pin M8 socket. Please note: Max cable length < 3m 12.2 ALARM With the option „ALARM“...