GHM GREISINGER EB-Logg 80K Series Installation And Operating Manual

Data logger for temperature

Advertisement

Quick Links

E40.0.1X.6C-07
from version 1.0
Please read these instructions carefully before use!
Please consider the safety instructions!
Please keep for future reference!
GHM GROUP - Greisinger
GHM Messtechnik GmbH | Hans-Sachs-Str. 26 | 93128 Regenstauf | GERMANY
Tel.: +49 9402 9383-0 |
Installation and operating manual
Data logger for temperature
EB-Logg 80K...
info@greisinger.de
| www.greisinger.de
WEEE-Reg.-Nr. DE 93889386

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GREISINGER EB-Logg 80K Series and is the answer not in the manual?

Questions and answers

Summary of Contents for GHM GREISINGER EB-Logg 80K Series

  • Page 1 Please read these instructions carefully before use!  Please consider the safety instructions!  WEEE-Reg.-Nr. DE 93889386 Please keep for future reference! GHM GROUP - Greisinger GHM Messtechnik GmbH | Hans-Sachs-Str. 26 | 93128 Regenstauf | GERMANY Tel.: +49 9402 9383-0 | info@greisinger.de | www.greisinger.de...
  • Page 2: Table Of Contents

    Keep this document within easy reach near the device for consulting in case of doubt. © Copyright 2020 GHM Messtechnik GmbH / Standort Greisinger. All Rights Reserved. No part of this documentation may without previous written permission of the company GHM Messtechnik GmbH stored in some form, reproduced, pro- cessed, duplicated or spread become.
  • Page 3: Safety

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 3 of 14 2. Safety 2.1 Intended Use The loggers EB-Logg 80K and EB-Logg 80KH are especially designed for long-time monitoring of temperatures. The combination of low power consumption with high battery capacity ensure a long record- ing time.
  • Page 4: Safety Guidelines

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 4 of 14 2.4 Safety guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
  • Page 5: Product Description

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 5 of 14 3. Product description 3.1 Required accessory The logger is configured, started and read-out via the EASYBus-interface. Therefore the following accessories are required:  Level converter - RS232 <> EASYBus (i.e. EBW 1, EBW 64, EBW 240) - USB <>...
  • Page 6: Display And Control Elements

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 6 of 14 4. Display and control elements 4.1 Display  Main display  Secondary display   Display element for max / min    Logg: indicates that logger is recording  ...
  • Page 7: Operation

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 7 of 14 6. Operation 6.1 Operating possibilities at the device - display selection Function Procedure Push button shortly The max-value is displayed for 4 seconds. (The max-value display function is signalled by the display ele- Display max value ment “MAX”).
  • Page 8: Operating Possibilities Via Software Gsoft 40K

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 8 of 14 Push button for about 5 seconds. The main display shows “HoLd”. The secondary display shows “no”. To stop recording select “YES” with the arrow key (button ) and verify with Stop recording Note: If no key is pressed for more than 2 min, the menu is quit without saving.
  • Page 9: Operating Displays

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 9 of 14 8. Operating displays The logger provides two LCD-displays: 7 mm (main display) and 5.8 mm (secondary display). 8.1 Measured value display The LCD mainly displays the measured values: MEASURED VALUE DISPLAY a) main display: temperature [°C] sec.
  • Page 10: System Messages

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 10 of 14 8.3 System messages BATTERY • display of the BAT-arrow left hand down: The battery is almost spent and needs to be replaced as soon as possible. The data recording is still active. •...
  • Page 11: Specifications

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 11 of 14 9. Specifications Measuring range: -30.0 … +60.0 °C EB-Logg 80K -50.0 … 150.0 °C EB-Logg 80KH EB-Logg 80KH…SMB1 -50… 400 °C EB-Logg 80KH…SMB2 -200… 500 °C EB-Logg 80KH…SMB4 -200.0 … 150.0 °C Resolution 0.1 °C or 1°...
  • Page 12: Decommissioning, Reshipment And Disposal

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 12 of 14 Operating temperature -30 … +60 °C Housing -50 … +200 °C Sensor cable: silicone -50 … +400 °C Sensor cable: glass fiber -200 … +250 °C Sensor cable: teflon -20 … +105 °C Sensor cable: PVC -30 …...
  • Page 13: Frequently Asked Questions [Faq]

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 13 of 14 11. Frequently asked questions [FAQ] Problem: The logger cannot be stopped via keys. “Logger stop via buttons disabled” has been activated at the configu- Possible reason: ration of the logger. Deactivate this function by means of GSOFT 40K (at tab „settings“). Remedy: Problem: The logger cannot be stopped both via keys and GSOFT 40K.
  • Page 14: Device Options

    Operating Manual EB-Logg 80K… E40.0.1X.6C-07 page 14 of 14 12. Device options Additional information’s for options of the EB-Logg 80K… . 12.1 AFK, detachable sensor cable For the “AFK” option, the Pt1000 is connected via a 4-pin M8 socket. Please note: Max cable length < 3m 12.2 ALARM With the option „ALARM“...