1. MOUNTING

The memory card interface unit can be flush mounted in a console, or mountd on a desktop or the
overhead.
Choose a mounting location for the unit considering the following points:
• Leave sufficient space around the unit to facilitate checking and maintenance. See outline
drawing at the back of this manual for recommended maintenance space.
• Locate the unit well away from exhaust gases and other active gases.
• The location should be well ventilated.
• Choose a location where shock and vibration are minimal.
• Only the front panel is waterproofed.
Note: For flush mount or bulkhead mount, the DIP switch setting should be completed before
mounting. See page 8.
1.1

Flush Mounting

1. Prepare a cutout in the mounting location as below.
2. Screw four threaded rod (M4×50, supplied) into holes on the front panel (reverse side).
Screw threaded rods into
3. Insert the unit into the cutout made at step 1.
4. Fix the unit with four spring, flat washers, and hex. nuts.
these holes.
Rear view
150.5+0.5
143+1
1
Threaded
rod