Electrical Connection - Zanussi ZOP37987XU User Manual

Table of Contents

Advertisement

Depth of the appliance
Built in depth of the
appliance
Depth with open door
Ventilation opening
minimum size. Opening
placed on the bottom
rear side
Mounting screws

ELECTRICAL CONNECTION

WARNING! Risk of fire and electric
shock.
All electrical connections should be made by a
qualified electrician.
The appliance must be earthed.
Make sure that the parameters on the rating
plate are compatible with the electrical ratings
of the mains power supply.
Always use a correctly installed shockproof
socket.
Do not use multi-plug adapters and extension
cables.
Make sure not to cause damage to the mains
plug and to the mains cable. Should the mains
cable need to be replaced, this must be carried
out by our Authorised Service Centre.
Do not let mains cables touch or come near the
appliance door or the niche below the
appliance, especially when it operates or the
door is hot.
The shock protection of live and insulated parts
must be fastened in such a way that it cannot be
removed without tools.
Connect the mains plug to the mains socket
only at the end of the installation. Make sure that
there is access to the mains plug after the
installation.
If the mains socket is loose, do not connect the
mains plug.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
Use only correct isolation devices: line
protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips
and contactors.
The electrical installation must have an isolation
device which lets you disconnect the appliance
from the mains at all poles. The isolation device
must have a contact opening width of minimum
3 mm.
4
569 mm
548 mm
1022 mm
Cable types applicable for installation or re-
560x20 mm
4x25 mm
For the section of the cable refer to the total power
on the rating plate. You can also refer to the table:
The earth cord (green / yellow cable) must be 2 cm
longer than phase and neutral cables (blue and
brown cables).
Cable types applicable for installation or
replacement for UK only
UK and Ireland only. This appliance is fitted with a
13 A mains plug. If it is necessary to change the
mains plug fuse, use only a 13 A ASTA (BS 1362)
fuse. Minimum size cable / flex: 1,5 mm² .
USE
Fully close the appliance door before you
connect the mains plug to the mains socket.
This appliance is supplied without a main plug
and a main cable.
placement for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
Total power (W)
maximum 1380
maximum 2300
maximum 3680
Connection
Min. size ca-
via
ble / flex
Oven Con-
2,5 mm²
trol Circuit
WARNING! Risk of injury, burns and
electric shock or explosion.
This appliance is for household use only.
Do not change the specification of this
appliance.
Make sure that the ventilation openings are not
blocked.
Section of the cable
(mm²)
3 x 0.75
3 x 1
3 x 1.5
Cable / flex
type / Fuse
PVC / PVC
twin and earth /
15 A min.
PVC / PVC
twin and earth /
20 A max.

Advertisement

Table of Contents
loading