Viking E-1600-03B Manual page 4

Ada compliant emergency phones with built-in digital voice announcer
Hide thumbs Also See for E-1600-03B:
Table of Contents

Advertisement

E
-
1
6
0
0
-
2
0
E
-
1
6
0
0
-
2
0
Dimensions: Overall - 127mm x 127 x 57mm (5.0" x 5.0"
x 2.25"), Plastic Electrical Box - 102mm x 102mm x 54mm
(4.0" x 4.0" x 2.14")
Shipping Weight: 1 kg (2.12 lbs.)
Front Panel Material:
14 gauge Marine grade 316
brushed stainless steel
Connections: Gel-filled butt connectors
Front View of
Plastic Rough-In
Box (included)
Wire knock out
(2) Standard flat head dry wall
(sheet rock) screws (not included)
The black plastic rough-in box (part # 259576) may be
purchased separately (Example: Mounting boxes to
studs before the walls are finished for flush installa-
tion). Go to www.vikingelectronics.com and click on
"Spare Parts" to order these rough-in boxes.
Important: The E-1600-20A will NOT mount to a standard double gang box.
* Note: Peel off paper liner and adhere gasket to the back of the faceplate, centering it over
the four corner mounting holes.
** Caution: When warm air comes in contact with cold surfaces, such as outside walls and
conduits, it causes condensation. To prevent condensation from accumulating inside the E-1600-20A always bring conduit into the bottom of the unit. If
this is not possible, drill a 1/4" diameter hole in the bottom of the black plastic box.
E
-
1
6
0
0
-
3
0
E
-
1
6
0
0
-
3
0
Dimensions: Overall - 127mm x 127 x 57mm (5.0" x 5.0"
x 2.25"), Plastic Electrical Box - 102mm x 102mm x 54mm
(4.0" x 4.0" x 2.14")
Shipping Weight: 1 kg (2.12 lbs.)
Front Panel Material:
14 gauge Marine grade 316
brushed stainless steel
Connections: Gel-filled butt connectors
Front View of
Plastic Rough-In
Box (included)
Wire knock out
(2) Standard flat head dry wall
(sheet rock) screws (not included)
The black plastic rough-in box (part # 259576) may be
purchased separately (Example: Mounting boxes to
studs before the walls are finished for flush installation).
Go to www.vikingelectronics.com and click on "Spare
Parts" to order these rough-in boxes.
** Important: Optional Braille "Push for Help" label should be adhered to the faceplate in ADA applications. Clean surface with isopropyl alco-
hol, peel off backing and press firmly to the front panel in location as shown above.
*** Caution: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation. To prevent con-
densation from accumulating inside the E-1600-30A always bring conduit into the bottom of the unit. If this is not possible, drill a 1/4" diameter
4
hole in the bottom of the black plastic box.
A
A
(
o
p
t
i
o
n
a
l
E
(
o
p
t
i
o
n
a
l
E
2.1"
4.0"
N C Y
R G E
E M E
N E
P H O
P
H E L
I N F O
L
C A L
T E D
N E C
C O N
"Help" Push to Call Button
Call Connected Red LED
"Info" Push to Call Button
(4) 6-32 X 3/4" Marine grade 316 stainless steel,
flat head, T-10 Torx Security Screws and Drive Bit (included)
Condensation Drain Hole
A
A
(
o
p
t
i
o
n
a
l
E
(
o
p
t
i
o
n
a
l
E
2.1"
4.0"
T E D
N E C
C O N
(4) 6-32 X 3/4" Marine grade 316 stainless steel, flat head, T-10 Torx Security Screws and Drive Bit (included)
* Note: Peel off paper liner and adhere gasket to the back of the faceplate, centering it over the
four corner mounting holes.
W
P
a
v
a
i
l
a
b
l
e
)
W
P
a
v
a
i
l
a
b
l
e
)
Optional Enhanced Weather Protection (EWP): The optional EWP products feature
foam rubber gaskets and boots, sealed connections, gel-filled butt connectors, as well as
urethane or thermal plastic potted circuit boards. See DOD# 859.
Mounting with Plastic Rough-In Box (included): Flush into walls, mounts to side of wall
stud Mounting with Optional VE-5x5: Surface mount to walls, single gang boxes, dou-
ble gang boxes, posts, or to a Viking VE-GNP Gooseneck pedestal (see options below).
Note: When mounting outside to rough or uneven surfaces (brick, stucco, etc.) apply a
bead of clear silicone caulking around the top edge and sides of faceplate or VE-5x5.
* Adhere gasket to front panel,
centering over mounting holes
5.22"
5.0"
5.14"
Grade 2 Braille
Label
Marine grade 316 stainless
2.25"
steel faceplate and push
button switches
(sealed per IP67)
W
P
a
v
a
i
l
a
b
l
e
)
W
P
a
v
a
i
l
a
b
l
e
)
Optional Enhanced Weather Protection (EWP): The optional EWP products feature
foam rubber gaskets and boots, sealed connections, gel-filled butt connectors, as well as
urethane or thermal plastic potted circuit boards. See DOD# 859.
Mounting with Plastic Rough-In Box (included): Flush into walls, mounts to side of wall
stud Mounting with Optional VE-5x5: Surface mount to walls, single gang boxes, dou-
ble gang boxes, posts, or to a Viking VE-GNP Gooseneck pedestal (as shown above).
Note: When mounting outside to rough or uneven surfaces (brick, stucco, etc.) apply a
bead of clear silicone caulking around the top edge and sides of faceplate or VE-5x5.
* Adhere gasket to front panel,
centering over mounting holes
5.22"
5.0"
Call Connected
Red LED
5.14"
Push to Call Button
Marine grade 316 stainless
2.25"
steel faceplate and push
button switches
(sealed per IP67)
Condensation Drain Hole
**Optional Braille Label
3.25"
3.8"
Condensation
Drain Hole
** 3/4" Knockout
for conduit
Front View of Optional
VE-5x5 (not included)
(4) 0.38" diameter
(4) 0.2 x 0.43 slots
for double gang box
(2) 0.2 x 0.43 slots
for single gang box
3.0" 3.3"
** 3/4"
Knockout
3.0"
Rear View of VE-5x5
(not included)
(4) 0.38" diameter
3.25"
(4) 0.2 x 0.43 slots
for double gang box
(2) 0.2 x 0.43 slots
for single gang box
Condensation
Drain Hole
*** 3/4" Knockout
for conduit
Front View of Optional
VE-5x5 (not included)
10.5"
39.5"
42"
Side View of VE-GNP
(not included)
3.0" 3.3"