State Water Heaters 310C Installation Manual And Owner's Manual page 19

On-demand water heater
Table of Contents

Advertisement

Maximum delivery Capacity of Cubic Feet of Gas per Hour of IPS Pipe carrying Natural Gas with 0.60 Specific Gravity
Based on Pressure Drop of 0.5" W.C.
Based on Energy Content of 1,000 BTU/Cubic ft.: The water heater requires 140 Cubic ft./hr for the 110C, 190
Cubic ft./hr for 310C, and 199 Cubic ft./hr for the 510C model.
Pipe Size
Diameter:
10'
20'
(3.0)
(6.1)
in.
1/2"
172
118
3/4"
360
247
1"
678
466
1
1,309 957
1/4"
1
2,090 1,430 1,150 985
1/2"
2"
4,020 2,760 2,220 1,900 1,680 1,520 1,400 1,300 1,220 1,160 1,020 928
Maximum Capacity of Propane (LP) Based on 11" W.C. supply pressure at a 0.5" W.C. pressure drop
Pipe Size
10'
20'
Diameter
(3.0)
(6.1)
268
184
1/2"
3/4"
567
393
1,071
732
1"
2,205 1,496 1,212 1,039
1
1/4"
1
3,307 2,299 1,858 1,559 1,417 1,275 1,181 1,086 1,023
1/2"
6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496 1,260
2"
Gas sizing example
(Natural Gas)
199,000 BTU/h
5' (1.5 m) Length
1-1/4" Pipe size
5' (1.5 m) Length
1-1/4" Pipe size
Gas meter
gas line supplying gas to more than one appliance (Ex: Point A to Point B), add up the cubic ft. per hour requirements
of the appliances that are being supplied by that section, and size to the farthest appliance.
For Example: The section from A to B supplies gas to the furnace, range and dryer. Adding up the BTU/h requirements
and dividing by 1,000 yields a cubic ft. per hour requirement of 220 cubic ft. of gas per hour. The farthest appliance
is the range, which is 50 ft. (15.2 m) away from the meter. According to the chart above, the 50-ft. (15.2 m) column
shows that Section A to B must be 1" in order to supply 220 cubic ft per hour.
-Natural Gas Supply Piping-
Length: ft. (m)
30'
40'
50'
60'
(9.1)
(12.2)
(15.2)
(18.3)
95
81
72
65
199
170
151
137
374
320
284
257
768
657
583
528
873
791
-Propane (LP) Supply Piping-
Length: ft. (m)
30'
40'
50'
60'
(9.1)
(12.2)
(15.2)
(18.3)
148
126
112
101
315
267
237
217
590
504
448
409
913
834
Water
heater
10' (3.1 m) Length
3/4" Pipe size
15' (4.6 m) Length
1" Pipe size
B
A
Length
10' (3.1 m)
1" Pipe size
10' (3.1 m) Length
3/4" Pipe size
Furnace
120,000 BTU/h
19
Sold by www.GadgetsGo.com Authorized Dealer
Unit: Cubic feet per hour
70'
80'
90'
100'
(21.3)
(24.4)
(27.4)
(30.5)
60
56
52
50
126
117
110
104
237
220
207
195
486
452
424
400
728
677
635
600
70'
80'
90'
100'
(21.3)
(24.4)
(27.4)
(30.5)
93
87
82
77
196
185
173
162
378
346
322
307
771
724
677
630
976
Dryer
35,000 BTU/h
Length
10' (3.1 m)
1/2" Pipe size
15' (4.6 m) Length
1/2" Pipe size
C
Range
65,000 BTU/h
Page
Installation Manual
Installation
125'
150'
200'
(38.1)
(45.7)
(61.0)
44
40
34
92
83
71
173
157
134
355
322
275
532
482
412
794
Unit: kBTU per hour
125'
150'
200'
(38.1)
(45.7)
(61.0)
68
62
53
146
132
112
275
252
213
567
511
440
866
787
675
Based on Energy
Content of 1,000
BTU/Cubic ft:
Divide
each
appliance's BTU/h
requirement
by
1,000 BTU/ft
to get
3
the appliances ft
/h
3
requirement.
Take into account
the distance the
appliance is from
the gas meter, then
look in the above
gas chart to properly
size the line.
For sections of the